NCK alarms/ISO alarms
06/2007 Overview of alarms
2-61
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
10700 Channel %1 block %2 NCK protection zone %3 violated during automatic
or MDI mode
Parameters: %1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions: The workpiece-related NCK protection zone has been violated. Note that another tool-related protec-
tion zone is still active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Protection zone can be traversed after a new NC Start.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10701 Channel %1 block %2 channel-specific protection zone %3 violated
during automatic or MDI mode
Parameters: %1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions: The workpiece-related channel-specific protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be traversed after a
new NC Start.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Protection zone can be traversed after a new NC Start.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10702 Channel %1 NCK protection zone %2 violated during manual mode
Parameters: %1 = Channel number
%2 = Protection zone number
Definitions: The workpiece-related NCK protection zone has been violated. Note that another tool-related protec-
tion zone is still active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Protection zone can be traversed after a new NC Start.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
10703 Channel %1 channel-specific protection zone %2 violated during manual
mode
Parameters: %1 = Channel number
%2 = Protection zone number
Definitions: The workpiece-related channel-specific protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be traversed after a
new NC Start.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Protection zone can be traversed after a new NC Start.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.