Siemens XPS15F Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro ne Siemens XPS15F. Siemens XPS15F Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - XPS/XCTTRANSDUCERS

XPS/XCT SERIESTRANSDUCERSXPS/XCTTRANSDUCERSInstruction Manual December 2001

Strany 2 - Disclaimer of Liability

INTERCONNECTIONFor EnviroRangerERS 500 only,connect all threewires separately.When connecting to an EnviroRanger ERS 500, do NOT use coaxialcable, us

Strany 3 - ABOUT THE TRANSDUCER

DO’S AND DON’TSInstallation shall only be performed by qualified personnel and in accordance with local governing regulations.Do not route cable openl

Strany 4 - SIRA 01ATEX5262X

APPLICATIONS The transducer is to be used only in the manner outlined in this instruction manual.Normally, the transducer requires no cleaning or mai

Strany 5 - SPECIFICATIONS

LIQUID APPLICATIONS - SUBMERGENCEIn applications where flooding is possible the transducer▼ can be fitted with a submergenceshield. The shield acts a

Strany 6 - * nominal

LIQUID APPLICATIONS - STANDPIPESIn many applications access must be made via a standpipe. In such cases, Milltronics canprovide factory bonded flanged

Strany 7 - (typical model)

LIQUID APPLICATIONS - VOLUME1. Beam should not detect bin bottom. If this occurs use range extension parameters (on transceivers where available) to o

Strany 8 - Submersible

LIQUID APPLICATIONS - WATER / WASTEWATERDIFFERENTIAL LEVELPUMP CONTROLSEWAGE LIFT16 XPS/XCT Transducers 7ML19981AK01.2

Strany 9

SOLIDS APPLICATIONS - TYPICAL3. Transducer too close to material inlet. Falling material will intersect sound beam and cause erroneous rea

Strany 10 - Coaxial Extension

SOLIDS APPLICATIONS - SPECIALSTORAGE BIN WITH AGITATOR1. Transducer should be kept away from infeed.2. Where agitators are in use, use the Agitator Di

Strany 11 - DO’S AND DON’TS

INSTALLATION DIAGRAM See Milltronics drawing number 0-9650017Z-DI-A for current drawing status.7ML19981AK01.2 XPS/XCT Transducers 19

Strany 12 - APPLICATIONS

© Siemens Milltronics Process Instruments Inc. 2001Safety GuidelinesWarning notices must be observed to ensure personal safety as well as that of oth

Strany 13 - on applicable models

FOR CANADIAN HAZARDOUS INSTALLATIONS ONLYSee Milltronics drawing number 0-8850004Z-DI-A for current drawing status.20 XPS/XCT Transducers 7ML19981AK01

Strany 14

NotesNotes.fm Page 2 Thursday, October 11, 2001 8:48 AM

Strany 15 - LIQUID APPLICATIONS - VOLUME

NotesNotes.fm Page 1 Thursday, October 11, 2001 8:48 AM

Strany 16 - DIFFERENTIAL LEVEL

IQ300IX.fm Page 5 Tuesday, October 2, 2001 1:43 PM

Strany 18 - SOLIDS APPLICATIONS - SPECIAL

ABOUT THE TRANSDUCERThe Echomax XPS / XCT series of transducers operates in association with Milltronics ultrasonic level monitoring products.The tran

Strany 19 - INSTALLATION DIAGRAM

XPS D Series - Certificate SIRA 01ATEX5262XThis equipment may be used in all hazardous dust zones with all conductive andnon-conductive dusts. The Typ

Strany 20

7ML19981AK01.2 XPS/XCT Transducers 5SPECIFICATIONSModel :XPS - 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT - 12MeasurementRange,0.3 - 10 0.3 - 15 0.6 -

Strany 21

OUTLINE AND DIMENSIONSradiating faceoptional submergence shieldrefer to associated instructionsoptional bonded flangerefer to associated instructionss

Strany 22

MOUNTINGDO’S AND DON’TSSpecial handling precautions must be taken to protect the face of the transducer from anydamage.Mount the transducer so that it

Strany 23

MOUNTING - LIQUID APPLICATIONSFlexible ConduitBracketSubmersiblePlywoodrigid metal conduitcouplingtransducersafetychainflexibleconduitsteel channelcou

Strany 24 - *7ml19981ak01*

MOUNTING - LIQUID APPLICATIONS (cont’d)nipple welded to blind flangecustomer flange, flat face onlyfactory flanged transducerboltgasketnutcouplingCust

Komentáře k této Příručce

Žádné komentáře