TC12 General Handbook
666/HB/43100/000 Page i Issue 9
SIEMENS TRAFFIC CONTROLS,
Sopers Lane,
POOLE, Dorset.
BH17 7ER.
SYSTEM: TC12
TC12 General Handbook
PREPARED: A Pickering
FUNCTION: Engineer
This document is electronically held and approved
ISSUE: REF: DATE:
1 19/12/92
2 19/01/93
3 05/05/93
4 28/04/94
5 08/05/97
6 26/01/99
7 20/06/00
8 09/01/02
9 TS003024 13/01/2006
© Siemens plc. 2002 All rights reserved.
The information contained herein is the property of Siemens plc. and is supplied without liability for errors
or omissions. No part may be reproduced or used except as authorized by contract or other written
permission. The copyright and the foregoing restriction on reproduction and use extend to all media in
which the information may be embodied.
Zobrazit stránku 0
1 2 3 4 5 6 ... 38 39

Shrnutí obsahu

Strany 1

TC12 General Handbook 666/HB/43100/000 Page i Issue 9 SIEMENS TRAFFIC CONTROLS, Sopers Lane, POOLE, Dorset. BH17 7ER. SYSTEM: TC12 TC12

Strany 2

TC12 General Handbook 666/HB/43100/000 Page 2-2 Issue 9 2.5 Size and Weight 2.5.1 Instation Height 1601mm Width 600mm Depth 800mm Cabinet

Strany 3

TC12 General Handbook 666/HB/43100/000 Page 2-3 Issue 9 2.7 General Overview TC12 is a telecommunications system designed for Urban Traffic Con

Strany 4

TC12 General Handbook 666/HB/43100/000 Page 2-4 Issue 9 Figure 1 - OVERVIEW OF TC12 SYSTEM UTCTCCPCITUOTUCONTROLLEREthernetSIPV.24To Remote

Strany 5

TC12 General Handbook 666/HB/43100/000 Page 3-1 Issue 9 3. MODEM USERS GUIDE The Modems installed in the Instation cabinet have been installe

Strany 6 - TABLE OF CONTENTS

TC12 General Handbook 666/HB/43100/000 Page 4-1 Issue 9 4. SYSTEM HARDWARE 4.1 General The TC12 system comprises of the following equipment :

Strany 7

TC12 General Handbook 666/HB/43100/000 Page 4-2 Issue 9 The transformer board is used, when the system is in radial configuration, to split eac

Strany 8 - 1. INTRODUCTION

TC12 General Handbook 666/HB/43100/000 Page 4-3 Issue 9 Figure 2 - INSTATION CABINET PC Housed behind SIPSystem Fault Indication PanelITU or

Strany 9 - 2. SPECIFICATION

TC12 General Handbook 666/HB/43100/000 Page 4-4 Issue 9 Figure 3 - ITU RACK MODEM 1TRANSR1MODEM 2TRANSR2MODEM 3TRANSR3MODEM 4TRANSR41.5”PSU6U

Strany 10

TC12 General Handbook 666/HB/43100/000 Page 4-5 Issue 9 Figure 4 - DIGITAL OUTPUT RACK PSU6U RackDigital Output PCBs Figure 5 - OTU RACK PSU

Strany 11

TC12 General Handbook 666/HB/43100/000 Page 4-6 Issue 9 Figure 6 - INSTATION TEST SET FUSEOFFONModem ModeModem SetCarrier Detect LevelAtte

Strany 12 - CONTROLLER

TC12 General Handbook 666/HB/43100/000 Page ii Issue 9 ISSUE STATE Note :- Source of documents is shown under Type as below. 1=Paper, 2=VAX,

Strany 13 - 3. MODEM USERS GUIDE

TC12 General Handbook 666/HB/43100/000 Page 4-7 Issue 9 Figure 7 - OUTSTATION TEST SET FUSEOFFONModem ModeModem SetCarrier Detect LevelAtte

Strany 14 - 4. SYSTEM HARDWARE

TC12 General Handbook 666/HB/43100/000 Page 5-1 Issue 9 5. SYSTEM FACILITIES Each Instation can contain up to 4 racks of TC12 equipment. These

Strany 15

TC12 General Handbook 666/HB/43100/000 Page 5-2 Issue 9 EPS41 - Either Two or Four wire presentation Or BT Analogue Mu

Strany 16 - System Fault Indication Panel

TC12 General Handbook 666/HB/43100/000 Page 5-3 Issue 9 Figure 8 - MESSAGE FORMAT - FULL AND HALF DUPLEX CONTROLControl Message to all O

Strany 17

TC12 General Handbook 666/HB/43100/000 Page 5-4 Issue 9 Table 1 - MODEM CAPACITY Baud Rate Half Duplex Full Duplex No of OTUs 30

Strany 18 - Digital Output PCBs

TC12 General Handbook 666/HB/43100/000 Page 5-5 Issue 9 Table 2 - OTUS PER LINE (1200 BAUD FULL DUPLEX) No of Control Bytes No of Re

Strany 19 - Case Lid

TC12 General Handbook 666/HB/43100/000 Page 5-6 Issue 9 Table 3 - OTUS PER LINE (1200 BAUD HALF DUPLEX) No of Control Bytes No of Re

Strany 20 - CONNECTION

TC12 General Handbook 666/HB/43100/000 Page 5-7 Issue 9 Table 4 - OTUS PER LINE (600 BAUD FULL DUPLEX) No of Control Bytes No of Rep

Strany 21 - 5. SYSTEM FACILITIES

TC12 General Handbook 666/HB/43100/000 Page 5-8 Issue 9 Table 5 - OTUS PER LINE (600 BAUD HALF DUPLEX) No of Control Bytes No of Rep

Strany 22

TC12 General Handbook 666/HB/43100/000 Page 5-9 Issue 9 Table 6 - OTUS PER LINE (300 BAUD FULL DUPLEX) No of Control Bytes No of Rep

Strany 23

TC12 General Handbook 666/HB/43100/000 Page iii Issue 9 SAFETY WARNING In the interests of health and safety, when using or servicing this

Strany 24

TC12 General Handbook 666/HB/43100/000 Page 5-10 Issue 9 Table 7 - OTUS PER LINE (300 BAUD HALF DUPLEX) No of Control Bytes No of Re

Strany 25

TC12 General Handbook 666/HB/43100/000 Page 5-11 Issue 9 5.2 Instation Facilities See Figure 9 for a diagram of the Instation system. 5.2.

Strany 26

TC12 General Handbook 666/HB/43100/000 Page 5-12 Issue 9 Figure 9 - INSTATION SYSTEM TCCEthernetPCDigital I/OI.M.D’sV. 2 44416 per IMDPSUCard

Strany 27

TC12 General Handbook 666/HB/43100/000 Page 5-13 Issue 9 5.3 Free-standing Outstation Facilities The Outstation can be configured to provide t

Strany 28

TC12 General Handbook 666/HB/43100/000 Page 5-14 Issue 9 5.3.6 Instation Communications Method The Freestanding OTU can be fitted with a daugh

Strany 29

TC12 General Handbook 666/HB/43100/000 Page 5-15 Issue 9 5.4.1.5 Handset The handset is used with the LMU to configure the system, assigning ph

Strany 30

TC12 General Handbook 666/HB/43100/000 Page 5-16 Issue 9 - stuck active (1 to 255 minutes) and stuck inactive (1 to 255 hours) timing limits

Strany 31

TC12 General Handbook 666/HB/43100/000 Page 5-17 Issue 9 5.6.4 Configurable options If no loops are configured for HIOCC then the HIOCC facilit

Strany 32 - Transmission Unit

TC12 General Handbook 666/HB/43100/000 Page 5-18 Issue 9 5.6.8 Outstation Mode In this mode the ITS replaces selected OTU. The ITS displays any

Strany 33

TC12 General Handbook 666/HB/43100/000 Page 6-1 Issue 9 6. INTEGRAL OUTSTATION TRANSMISSION UNIT (OTU) 6.1 General Overview This section desc

Strany 34

TC12 General Handbook 666/HB/43100/000 Page iv Issue 9 TELECOMMUNICATIONS APPROVAL WARNING The TC12 Modems 667/1/22669/000, 667/1/22668/000 a

Strany 35

TC12 General Handbook 666/HB/43100/000 Page v Issue 9 PREFACE It is intended that this preface should guide the reader as to the use of this

Strany 36

TC12 General Handbook 666/HB/43100/000 Page vi Issue 9 TABLE OF CONTENTS 1. INTRODUCTION ...

Strany 37

TC12 General Handbook 666/HB/43100/000 Page vii Issue 9 5.4 Lamp Monitoring Facilities ...

Strany 38

TC12 General Handbook 666/HB/43100/000 Page 1-1 Issue 9 1. INTRODUCTION 1.1 Purpose This document describes to the user the TC12 Traffic Contro

Strany 39

TC12 General Handbook 666/HB/43100/000 Page 2-1 Issue 9 2. SPECIFICATION 2.1 Mains Voltage Ranges Instation 98 - 132Vrms / 198 - 264Vrms