SIMATIC FS600 laser scanner
Standard laser scanner
3/95
Siemens FS 10 · 2008
3
■
Technical specifications
Type Standard laser scanner
Personnel protective field
Detection range
0 ... 4 m
Luminance factor
min. 1.8 %
Object size/diameter
70 mm (cylindrical test body)
Response time
• Dual evaluation (2 scans) 80 ms
• Adjustable up to 16 scans
640 ms
No. of protective fields
4 (can be selected
via switching inputs)
Output
2 fail-safe pnp transistor outputs
(24 V, 250 mA)
Safety category
• To DIN V 19250 Requirements class 4
• To EN 954-1
Category 3 (single-fault-proof)
• To IEC 61496-1, EN 61496-3
Type 3
Start
Start-up testing and start-up
inhibit can be set separately.
restart
160 ms to 10 s adjustable
or manual
Supplement with deactivated dust
suppression
83 mm
Supplement with activated dust
suppression
• Protective field size < 3.5 m 83 mm
• Protective field size > 3.5 m
100 mm
Additional supplement in the case
of existing retro-reflectors or highly
reflective surfaces (e.g. certain
metals or ceramics) in the scan
plane
• More than 1.2 m behind the
protective field line
0 mm
• In protective field or up to 1.2 m
behind the protective field line
110 mm
Warning field
Detection range
0 ... 15 m
Luminance factor
min. 20 %
Object size
150 mm × 150 mm
Response time
• Dual evaluation (2 scans) 80 ms
• Adjustable up to 16 scans
640 ms
No. of warning fields
4 (can be selected
via switching inputs)
Output
pnp transistor output
(max. 100 mA)
Contour measurement
Detection range
0 ... 50 m
Luminance factor
min. 20 %
Object size
–
Output
RS 232 serial interface (10 m),
RS 422 (50 m)
Radial resolution
5 mm
Lateral resolution
0.36°
Power supply
Operating voltage
Supply (to IEC 60742) with safety
isolating transformer or similar for
DC/DC transducers
• External supply
24 V DC, –30 … +20 %*
Current consumption
Approx. 300 mA
(use power pack with 2.5 A)
Power consumption with 24 V
8 W plus output load
Overcurrent protection
Via 1.25 A fuse, medium time lag,
in control cabinet
Overvoltage protection
With safe final shutdown
Voltage dips
To EN 61496-1
Protective conductor
Must not be connected
Inputs
Restart/reset
Connection of a command unit for
operating mode with restart inhibit
and/or device reset, dynamically
monitored, 24 V DC optically
decoupled
Field pair changeover
Selection from 4 field pairs via
4 control leads with internal moni-
toring (1 field pair = 1 protective
field and 1 warning field), 24 V DC
optically decoupled
Signal definition
• High (logical 1) 16 ... 30 V
• Low (logical 0)
< 3 V
Parameter assignment
Operating software
Communication and parameter-
ization software under Windows
95/98/NT/2000/XP with safe pro-
gramming protocol
Interfaces
For device parameterization field
definition
RS232, RS422
Outputs
Protective field
2 × safe semiconductor output,
pnp, max. 250 mA short-circuit
monitored, overcurrent protected
Warning field/pollution/fault
pnp transistor output
(max. 100 mA)
Load characteristics, max. values
Low-pass response
• Limit frequency f
g
< 1 kHz
• Capacitance C
load
< 100 nF
Level
• High (OSSD) U
b
- 3.2 V
• Low (OSSD)
< 2 V
• High (alarm active)
U
b
-4 V
• Low (alarm inactive)
< 2 V
Type
Standard laser scanner