Siemens Java TC65 Uživatelský manuál Strana 31

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 90
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 30
TC65 JAVA User's Guide
Strictly confidential / Released
s
TC65 JAVA User's Guide_V05 Page 31 of 90 26.09.2005
5.9.3.1 Plain Serial Interface
Scenario: A device is connected to ASC0 (refer to 4.2.4). The Java application must handle
data input and output streams. A simple Java application (with only one thread) which loops
incoming data directly to output, reaches data rates up to 180kbit/s. Test conditions:
hardware flow control enabled (<autorts> and <autocts>), 8N1, and baud rate on ASC0 set
to 230kbaud (-> theoretical maximum: 184kbit/s net data rate).
TC65
Java
application
(looping data)
ASC1
Figure 13: Scenario for testing data rates on ASC1
5.9.3.2 Voice Call in Parallel
Same scenario as in section 5.9.3.1, but with a voice call added. The application reflects
incoming data directly to output and, additionally, handles an incoming voice call. The data
rates are also up to 180kbit/s. Test conditions: same as in Sect. 5.9.3.1.
i
n
c
o
m
i
n
g
v
o
i
c
e
c
a
l
l
TC65
Java
application
(looping data)
ASC1
Figure 14: Scenario for testing data rates on ASC1 with a voice call in parallel