Wound rotor Inspection
Brushes should be inspected every 1000
running hours or at three monthly intervals if
this is a shorter period of time.
The inspection should include checks for
brush wear and tensioning. Build up of
carbon dust should be removed using a
suitable dust extraction unit.
Replacement of brushes is recommended
when the brush is approximately a quarter of
the way down the brush holder. On calliper
type designs the brushes should be replaced
when 1/4” (5mm) of brush remains.
It is important that the correct grade of brush
be used as this significantly affects operation.
If in doubt please refer to Brook Crompton.
Hazardous area motors
In addition to the conditions referred to,
special requirements apply to motor types
Ex N, Ex nA, EEx e, EEx d, EEx de. Refer to
the approval certificate and appropriate
codes of practice eg BS 5435.
Spares and repairs
When ordering spares it is important to state
the motor serial number to ensure that the
correct spares will be supplied.
Notes
a fixing bolts, nuts, studs, screws, spacers or
washers are not included with these parts
and, if required, should be clearly specified
on the order in addition to the part
description number. The fixing duty and
part description reference number for
which they are required should also be
clearly stated
b bearings ordered direct from bearing
manufacturers must be specified as
follows:
63-90 CN bearing
100-355 C3 bearing
Enquiries
Please contact Brook Crompton or its Agents
for information on any aspects of the motor
performance that need clarifying.
Contact must be made prior to any remedial
action being taken under guarantee.
Please quote the motor number in all such
cases with full details of the problem.
Policy
Our policy is one of continuous improvement
and we reserve the right to alter any detail of
our products at any time without giving
notice.
103-4E Issue 2 Spare parts, installation and maintenance of ac electric induction motors
Endshield fixing bolt torques
63
71
80
90S/L
100L
112M
132S/M
160M/L
180M/L
200L
225S
225M
250S
250M
280S
280M
315S
315M
315L
355S/M/L
56
143/145
182/184
213/215
254/256
284/286
324
326
364
365
404
405
444
445
504
505
585/6/7
Type
M4
M4
M5
M5
M6 (taptite)
M6 (taptite)
M6 (taptite)
M8 (taptite)
M10 (taptite)
M10*
M10*
M10*
M10*
M16*
M16*
M16*
M16*
M20*
M20*
M20*
1.5
1.5
5
5
8-10
8-10
8-10
29
52
52
52
52
52
220
220
220
220
400
400
400
1.1
1.1
3.7
3.7
5.9-7.4
5.9-7.4
5.9-7.4
21
38
38
38
38
38
162
162
162
162
295
295
295
5
5
20-24
20-24
28-32
28-32
38-42
52
52
52
52
220
220
220
220
400
400
400
3.7
3.7
14.7-17.7
14.7-17.7
20.5-23.6
20.5-23.6
27.8-30.7
38
38
38
38
162
162
162
162
295
295
295
52
52
52
52
220
220
220
220
400
400
400
38
38
38
38
162
162
162
162
295
295
295
Metric NEMA/CSA
Bolt dia W-DA
Aluminium frames
Torque
DF & W-DF
Cast iron frames
Torque
K-CF
Torque
Nm Lbf.FT Nm Lbf.FT Nm Lbf.FT
Foot fixing bolt torques
63
71
80
90S/L
100L
112M
132S/M
160M/L
180M/L
200L
225S
225M
250S
250M
280M
280L
315S
315M
315L
355S/M/L
56
143/145
182/184
213/215
254/256
284/286
324
326
364
365
404
405
444
445
504
505
585/6/7
Type
M5
M5
M8 (taptite)
M8 (taptite)
M8 (corflex)
M8 (corflex)
M8 (corflex)
M10
M10
M10*
M10*
M10*
M10*
M16*
M16*
M16*
M16*
M20*
M20*
M20*
6-7
6-7
24-25
24-25
32-35
32-35
32-35
68-72
68-72
4.5-5.2
4.5-5.2
17.7-18.4
17.7-18.4
23.6-25.8
23.6-25.8
23.6-25.8
50-53
50-53
52
52
52
52
220
220
220
220
400
400
400
38
38
38
38
162
162
162
162
295
295
295
Metric NEMA/CSA
Bolt dia W-DA
Aluminium frames
Torque
W-DF
Cast iron frames
Torque
Nm Lbf.FT Nm Lbf.FT
* High tensile socket headed bolts and square nuts must be used