T400 Controller Facilities Manual
667/EB/20200/000 Page i Issue 9
SIEMENS TRAFFIC CONTROLS LIMITED
Sopers Lane
POOLE Dorset.
BH17 7ER
SYSTEM/PROJECT/PRODUCT: T400 CONTROLLER
T400 CONTROLLER
FACILITIES MANUAL
PREPARED: A.Pickering APPROVED: J.P.Burgess
FUNCTION: Senior Engineer FUNCTION: Engineering Manager
SIGNATURE: SIGNATURE:
ISSUE: CHANGE REF.: DATE: APPROVED BY:
1 16/08/89
2 83/15948 15/02/91
3 83/16122 13/06/91
4 83/16700 24/09/92
5 83/16955 18/12/92
6 83/17014 20/01/93
7 83/17147 23/03/93
8 83/18623 22/05/96
9 Jan 1999
Siemens Traffic Controls Limited 1995 All rights reserved.
The information contained herein is the property of Siemens Traffic Controls Limited and is
supplied without liability for errors or omissions and no part may be reproduced, used or
disclosed except as authorized by contract or other written permission. The copyright and the
foregoing restriction on reproduction, use and disclosure extend to all the media in which this
information may be embodied.
(stcl-pub)
Zobrazit stránku 0
1 2 3 4 5 6 ... 307 308

Shrnutí obsahu

Strany 1 - FACILITIES MANUAL

T400 Controller Facilities Manual667/EB/20200/000 Page i Issue 9SIEMENS TRAFFIC CONTROLS LIMITEDSopers LanePOOLE Dorset.BH17 7ERSYSTEM/PROJECT/PRODUCT

Strany 2

T400 Controller Facilities Manual667/EB/20200/000 Page x Issue 916.1.4 SW1, SW2 and SW3 Pushbuttons...

Strany 3

T400 Controller Facilities Manual667/EB/20200/000 Page 9-40 Issue 99.7.2 Manual Step-on Mode Parallel Stage Streaming FacilitiesEach step is allocate

Strany 4

T400 Controller Facilities Manual667/EB/20200/000 Page 9-41 Issue 99.8 SELECTED FIXED TIME, CLF OR V.A. MODEManually selected ‘FT’, ‘CLF’ and ‘VA’ ar

Strany 5

T400 Controller Facilities Manual667/EB/20200/000 Page 9-42 Issue 9need to be carefully considered, if synchronisation with the rest of the system is

Strany 6

T400 Controller Facilities Manual667/EB/20200/000 Page 9-43 Issue 99.9.1 Example Of Simple Linked InstallationA simple linked installation covering t

Strany 7

T400 Controller Facilities Manual667/EB/20200/000 Page 9-44 Issue 9The group timers in each linking unit are fully synchronous and, provided the total

Strany 8

T400 Controller Facilities Manual667/EB/20200/000 Page 9-45 Issue 99.9.5 Group Influences0. GO TO VA - allows vehicle actuation to operate except tha

Strany 9

T400 Controller Facilities Manual667/EB/20200/000 Page 9-46 Issue 99.9.6 Examples Of PlansSee Figure 21.11.9.9.6(a) Plan 0The sequence will commence

Strany 10

T400 Controller Facilities Manual667/EB/20200/000 Page 9-47 Issue 9The example shown in Figure 9.7(a) would be for a two streamcontroller where Stream

Strany 11

T400 Controller Facilities Manual667/EB/20200/000 Page 9-48 Issue 9b)INFLUENCE SET 2Influence SetCombination ‘A’Influence SetCombination ‘B’GroupInfRe

Strany 12

T400 Controller Facilities Manual667/EB/20200/000 Page 9-49 Issue 9it would be outputting and how many seconds have elapsed within this group if thisp

Strany 13

T400 Controller Facilities Manual667/EB/20200/000 Page xi Issue 917.11.2 Alternative Max. sets...

Strany 14

T400 Controller Facilities Manual667/EB/20200/000 Page 9-50 Issue 9should be specified. If alternatives are specified, it is preferable for thealterna

Strany 15

T400 Controller Facilities Manual667/EB/20200/000 Page 9-51 Issue 9If required (specified by handset command), then every time a grouptime withinthe c

Strany 16

T400 Controller Facilities Manual667/EB/20200/000 Page 9-52 Issue 9Combination ‘A’ would be used for Stream 0, Influence Set Combination ‘B’ forStream

Strany 17 - 1. INTRODUCTION

T400 Controller Facilities Manual667/EB/20200/000 Page 9-53 Issue 99.10 VEHICLE ACTUATED (VA) MODEIn VA mode the controller monitors all demands, ext

Strany 18

T400 Controller Facilities Manual667/EB/20200/000 Page 9-54 Issue 9Figure 9.8 - EXAMPLE OF VA STAGE CHANGES AACEGSTAGE 2DSTAGE 1BSTAGE 3 STAGE 4EFEF‘I

Strany 19

T400 Controller Facilities Manual667/EB/20200/000 Page 9-55 Issue 99.10.2 Arterial Reversion Parallel Stage Streaming FacilitiesThere is an Arterial

Strany 20

T400 Controller Facilities Manual667/EB/20200/000 Page 9-56 Issue 99.11 FIXED TIME WORKINGThere are two methods of obtaining fixed time working:- Fi

Strany 21 - 2. STAGES

T400 Controller Facilities Manual667/EB/20200/000 Page 9-57 Issue 9If Fixed time to current maximum is to be the default/lowest mode of operation. The

Strany 22

T400 Controller Facilities Manual667/EB/20200/000 Page 9-58 Issue 9timer will start when all stages have appeared. This process will be repeated for e

Strany 23

T400 Controller Facilities Manual667/EB/20200/000 Page 9-59 Issue 99.12 MODE PRIORITYThe mode priority facility allows for the mode with the highest p

Strany 24

T400 Controller Facilities Manual667/EB/20200/000 Page xii Issue 921. EXAMPLE OF AN INTERSECTION ...

Strany 25

T400 Controller Facilities Manual667/EB/20200/000 Page 9-60 Issue 9Similarly to select Manual mode the MANUAL mode select button is selected and ifSEL

Strany 26

T400 Controller Facilities Manual667/EB/20200/000 Page 9-61 Issue 99.13 TIMER RELATIONSHIPSBelow is a simple diagram intended to indicate the relatio

Strany 27

T400 Controller Facilities Manual667/EB/20200/000 Page 10-1 Issue 910. STAGE MOVEMENT RESTRICTIONSWhen a specific stage change is required not to occ

Strany 28

T400 Controller Facilities Manual667/EB/20200/000 Page 10-2 Issue 910.1 PROHIBITED MOVESWhen a move to a stage is prohibited and there is a demand fo

Strany 29

T400 Controller Facilities Manual667/EB/20200/000 Page 10-3 Issue 9may be stage change conditions present for Stage 2 and ROW will go there beforeStag

Strany 30 - 3. PHASES

T400 Controller Facilities Manual667/EB/20200/000 Page 10-4 Issue 910.5 PREVENTED STAGES/PHASESThe deletion of a stage or phase, which may be achieved

Strany 31

T400 Controller Facilities Manual667/EB/20200/000 Page 11-1 Issue 911. THE MASTER TIME CLOCK SYSTEM11.1 INTRODUCTIONThe master time clock system (MTC

Strany 32

T400 Controller Facilities Manual667/EB/20200/000 Page 11-2 Issue 9If the mains fails for more than 30 days (this threshold is configurable and alsoal

Strany 33

T400 Controller Facilities Manual667/EB/20200/000 Page 12-1 Issue 912. THE EVENT TIMETABLE12.1 PLAN CHANGE/EVENT TIMETABLEThere are 64 entries in th

Strany 34

T400 Controller Facilities Manual667/EB/20200/000 Page 12-2 Issue 912.2.1 Synchronisation of Cableless Linking EquipmentSynchronisation of Cableless

Strany 35

T400 Controller Facilities Manual667/EB/20200/000 Page xiii Issue 9B.1 50-0-50 volt Controller ...

Strany 36

T400 Controller Facilities Manual667/EB/20200/000 Page 12-3 Issue 9inactive will set it permanently inactive. The state will continue until another ti

Strany 37

T400 Controller Facilities Manual667/EB/20200/000 Page 12-4 Issue 9If a real phase is deleted, then the signals will remain at red (or blackout in the

Strany 38

T400 Controller Facilities Manual667/EB/20200/000 Page 12-5 Issue 912.3.1 Event Switch Default StatesEvent Default StateMaxSwitch Set A and Priority

Strany 39

T400 Controller Facilities Manual667/EB/20200/000 Page 12-6 Issue 9At 12-30 Alternative Maximum Set D is introduced and Dummy Phase I remainsdeleted w

Strany 40

T400 Controller Facilities Manual667/EB/20200/000 Page 13-1 Issue 913. LINKING13.1 PELICAN CONTROLLERA link to an adjacent Pelican Controller may be

Strany 41

T400 Controller Facilities Manual667/EB/20200/000 Page 13-2 Issue 913.2 REPEAT PULSESThe Type 400 Controller may be linked to other traffic controller

Strany 42

T400 Controller Facilities Manual667/EB/20200/000 Page 14-1 Issue 914. ALTERNATIVE SIGNAL SEQUENCES AND FLASHING SIGNALS14.1 ALTERNATIVE SIGNAL SEQU

Strany 43 - 4. DEMANDS AND EXTENSIONS

T400 Controller Facilities Manual667/EB/20200/000 Page 14-2 Issue 9If this sequence is required, the pedestrian phase has to be programmed as a traffi

Strany 44

T400 Controller Facilities Manual667/EB/20200/000 Page 14-3 Issue 914.3 FLASHING SIGNALSThe signals on traffic, pedestrian and green arrow phases are

Strany 45

T400 Controller Facilities Manual667/EB/20200/000 Page 14-4 Issue 914.4 EXPORT SIGNAL SEQUENCESThe following is a list of some of the foreign signal

Strany 46 - 5. CALL/CANCEL

T400 Controller Facilities Manual667/EB/20200/000 Page xiv Issue 9TABLE OF FIGURESFIGURE 6.1 - SDE/SA LAYOUTS ...

Strany 47

T400 Controller Facilities Manual667/EB/20200/000 Page 14-5 Issue 9HONG KONG: Startup sequence:A 7-10 second blackout, followed by all red usually 8 s

Strany 48

T400 Controller Facilities Manual667/EB/20200/000 Page 15-1 Issue 915. INPUTS AND OUTPUTS15.1 INPUTS (I/P)Inputs into the controller may include the

Strany 49

T400 Controller Facilities Manual667/EB/20200/000 Page 15-2 Issue 915.5 PROVISION OF I/O ON EXPANSION I/O, MAIN PROCESSOR AND SDE/SABOARDSThere are 1

Strany 50

T400 Controller Facilities Manual667/EB/20200/000 Page 15-3 Issue 915.6.1 Cable AssembliesA cable assembly consists of a cable with one or two 12-way

Strany 51 - Figure 6.1 - SDE/SA LAYOUTS

T400 Controller Facilities Manual667/EB/20200/000 Page 15-4 Issue 915.7 PORT ALLOCATIONPort numbers are allocated as per the following table:Board Ty

Strany 52 - 7. ALL-RED DISPLAYS

T400 Controller Facilities Manual667/EB/20200/000 Page 15-5 Issue 9Figure 15.1 - BLOCK DIAGRAM OF MAIN PROCESSOR BOARDREARFRONTPOWER ON LED(GREEN)WATC

Strany 53

T400 Controller Facilities Manual667/EB/20200/000 Page 15-6 Issue 9Figure 15.2 - PCB POSITIONS AND LAYOUT OF PHASE DRIVER RIBBONCABLESPHASEDRIVERA-DI/

Strany 54

T400 Controller Facilities Manual667/EB/20200/000 Page 15-7 Issue 9Figure 15.3 - REAR VIEW OF PCB I/O CONNECTIONS (T400 LARGE SHOWN)PHASEDRIVERA-DPHAS

Strany 55

T400 Controller Facilities Manual667/EB/20200/000 Page 15-8 Issue 9Figure 15.4 - TERMINAL BLOCKS IN SMALL CONTROLLERTERMINALBLOCKSPCB MODULE(EXPANSION

Strany 56 - 8. PHASE DELAYS

T400 Controller Facilities Manual667/EB/20200/000 Page 15-9 Issue 9Figure 15.5 - TERMINAL BLOCKS IN LARGE CONTROLLERBB X T R NZDDCC AA Y W S PEELJGECA

Strany 57

T400 Controller Facilities Manual667/EB/20200/000 Page xv Issue 9FIGURE 21.3 - CUSTOMER SPEC SHEET EXAMPLE ... 21-

Strany 58

T400 Controller Facilities Manual667/EB/20200/000 Page 15-10 Issue 9Figure 15.6 - TERMINAL BLOCKS IN LARGE CONTROLLER (HONG KONG)SECOND PANEL (FITTED

Strany 59

T400 Controller Facilities Manual667/EB/20200/000 Page 15-11 Issue 915.8 ‘DET’ HANDSET COMMANDEach bit of each port has an I/O line number which is u

Strany 60

T400 Controller Facilities Manual667/EB/20200/000 Page 15-12 Issue 9An example of this is a stage that is required not to appear initially. The stage

Strany 61 - 9. MODES

T400 Controller Facilities Manual667/EB/20200/000 Page 15-13 Issue 915.9.1 DFM Timing15.9.1(a) Option 1The timing range of the DFM is 0 to 255 hours

Strany 62

T400 Controller Facilities Manual667/EB/20200/000 Page 15-14 Issue 9If the detector is active for greater than 60 minutes.If the detector is inactive

Strany 63

T400 Controller Facilities Manual667/EB/20200/000 Page 16-1 Issue 916. MANUAL PANELSee Figure 16.1.16.1 STANDARD FACILITIES (Intersection Controller)

Strany 64

T400 Controller Facilities Manual667/EB/20200/000 Page 16-2 Issue 916.1.6 DFM Reset Push-button (If Configured)The DFM RESET push-button extinguishes

Strany 65

T400 Controller Facilities Manual667/EB/20200/000 Page 16-3 Issue 9If more than three indicators are required, then the HURRY CALL active or HIGHERPRI

Strany 66

T400 Controller Facilities Manual667/EB/20200/000 Page 16-4 Issue 916.3 PELICAN MANUAL PANELThe Manual Panel used on a Pelican controller is essentia

Strany 67

T400 Controller Facilities Manual667/EB/20200/000 Page 16-5 Issue 9Figure 16.1 - MANUAL PANEL3CABINETALARMALLRED1 24 56 7NORMALMANUAL CONTROLMANUALFIX

Strany 68

T400 Controller Facilities Manual667/EB/20200/000 Page xvi Issue 9FIGURE 22.26 - CUSTOMER SPEC SHEET EXAMPLE ... 22-27

Strany 69

T400 Controller Facilities Manual667/EB/20200/000 Page 16-6 Issue 9Figure 16.2 - INTERNAL MANUAL PANEL (HONG KONG)3ALLRED124567NORMALMANUAL CONTROLMAN

Strany 70

T400 Controller Facilities Manual667/EB/20200/000 Page 17-1 Issue 917. PELICAN/PEDESTRIAN CONTROLLER17.1 GENERALThere are a number of pelican configu

Strany 71

T400 Controller Facilities Manual667/EB/20200/000 Page 17-2 Issue 917.1.2(c) Pre-timed Maximum Vehicle GreenThis is an alternative form of VA mode if

Strany 72

T400 Controller Facilities Manual667/EB/20200/000 Page 17-3 Issue 917.3 MANUAL PANEL FACILITIESA different manual panel is required for the T400 when

Strany 73

T400 Controller Facilities Manual667/EB/20200/000 Page 17-4 Issue 917.4 HANDSETOn street selection of pelican facilities by the handset can be carried

Strany 74

T400 Controller Facilities Manual667/EB/20200/000 Page 17-5 Issue 917.5 I/O LINE ALLOCATIONEach of the following functions may be allocated to an I/O

Strany 75

T400 Controller Facilities Manual667/EB/20200/000 Page 17-6 Issue 917.6 WAIT INDICATORSThis facility allows the user to select (via the handset) whet

Strany 76

T400 Controller Facilities Manual667/EB/20200/000 Page 17-7 Issue 917.10 DESCRIPTION OF I/O LINE FUNCTIONSPelican I/O SummaryControl Bits UTCTitle Bi

Strany 77

T400 Controller Facilities Manual667/EB/20200/000 Page 17-8 Issue 917.10.1 UTC Facilities (Control Bits)UTC Ped. Inhibit (PV)This input signal preven

Strany 78

T400 Controller Facilities Manual667/EB/20200/000 Page 17-9 Issue 9Switch to Alternative TimingsThis input signal forces the Pelican to switch to the

Strany 79

T400 Controller Facilities Manual667/EB/20200/000 Page 1-1 Issue 91. INTRODUCTIONThis manual refers to the facilities available in the Type 400 Contro

Strany 80

T400 Controller Facilities Manual667/EB/20200/000 Page 17-10 Issue 9Signals Off Confirm (LE)This output signal indicates that the signals on the CPU

Strany 81

T400 Controller Facilities Manual667/EB/20200/000 Page 17-11 Issue 9 (i) it will ignore the PV1 signal and revert to normal unlinked operationand on

Strany 82

T400 Controller Facilities Manual667/EB/20200/000 Page 17-12 Issue 9Link Out (Vehicle green confirm)This output signal is essentially a Vehicle Green

Strany 83

T400 Controller Facilities Manual667/EB/20200/000 Page 17-13 Issue 9NOTE: Pedestrian demands from UTC or local link operate as on the Pelicancontrolle

Strany 84

T400 Controller Facilities Manual667/EB/20200/000 Page 17-14 Issue 917.11 TIMESWITCH FACILITIES17.11.1 Switch Audio offThis facility allows the pelic

Strany 85

T400 Controller Facilities Manual667/EB/20200/000 Page 17-15 Issue 917.12.3 Special Detector checking.This facility is used in VA Mode. When enabled

Strany 86

T400 Controller Facilities Manual667/EB/20200/000 Page 17-16 Issue 9Figure 17.1 - Pelican Manual Panel (Standard)CABINETALARMCONT PEDDEMANDCONTVEHICLE

Strany 87

T400 Controller Facilities Manual667/EB/20200/000 Page 17-17 Issue 9Figure 17.2 - Pelican Manual panel (Basic)CABINETALARMOFFSIGNALSON

Strany 88

T400 Controller Facilities Manual667/EB/20200/000 Page 18-1 Issue 918. EQUIPMENT18.1 PHASE FACILITIESThe Intersection Controller can drive up to 16 re

Strany 89

T400 Controller Facilities Manual667/EB/20200/000 Page 18-2 Issue 918.3 PED. AUDIBLE / TACTILE INDICATION (MCE0141 CONTROLLERS ONLY)Items Required:K-

Strany 90

T400 Controller Facilities Manual667/EB/20200/000 Page 1-2 Issue 91.1 GLOSSARY OF TERMSAbbreviationsAC Alternating CurrentCET Cable Earth TerminalCLF

Strany 91

T400 Controller Facilities Manual667/EB/20200/000 Page 18-3 Issue 918.5 DUAL LEVEL AUDIBLESItems Required:Kit Of Parts to add secondary buzzer...

Strany 92

T400 Controller Facilities Manual667/EB/20200/000 Page 18-4 Issue 9DetectorsSiemens (ST) Self Tune Detectors MkII 667/1/17180/012 = 2 detector channel

Strany 93

T400 Controller Facilities Manual667/EB/20200/000 Page 18-5 Issue 9Alternatively, a special conditioning flag can be set from the MTC timetable to ind

Strany 94

T400 Controller Facilities Manual667/EB/20200/000 Page 18-6 Issue 918.12 POWERING EXTERNALLY SITUATED D-DETECTORS WITH PSU TYPE667/1/20654/000Items Re

Strany 95

T400 Controller Facilities Manual667/EB/20200/000 Page 18-7 Issue 9Figure 18.1 - PEDESTRIAN AUDIBLE INDICATION (SIGNAL HEAD MOUNTING)(Note: If it is r

Strany 96

T400 Controller Facilities Manual667/EB/20200/000 Page 18-8 Issue 9Figure 18.2 - PEDESTRIAN AUDIBLE INDICATION (CONTROLLER MOUNTING)(Note: If it is no

Strany 97

T400 Controller Facilities Manual667/EB/20200/000 Page 18-9 Issue 9Figure 18.3 - PEDESTRIAN TACTILE INDICATION (SIGNAL HEAD MOUNTING)(Note: If it is r

Strany 98

T400 Controller Facilities Manual667/EB/20200/000 Page 18-10 Issue 9Figure 18.4 - PEDESTRIAN TACTILE INDICATION (CONTROLLER MOUNTING)(Note: If it is n

Strany 99

T400 Controller Facilities Manual667/EB/20200/000 Page 18-11 Issue 9Figure 18.5 - POSSIBLE PCB CONFIGURATIONSPhaseDriverPhaseDriverPhaseDriverPhaseDri

Strany 100 - DOOR MICROSWITCH

T400 Controller Facilities Manual667/EB/20200/000 Page 18-12 Issue 9Figure 18.6 - FRONT VIEW OF THE TYPE 400 CONTROLLER (LARGE O/C)OTU or OMU (if fitt

Strany 101

T400 Controller Facilities Manual667/EB/20200/000 Page 1-3 Issue 9RLMU Red Lamp Monitor UnitRMS Root Mean SquareROW Right Of WayRTC Real Time ClockSA

Strany 102

T400 Controller Facilities Manual667/EB/20200/000 Page 18-13 Issue 9Figure 18.7 - FRONT VIEW OF THE TYPE 400 CONTROLLER (SMALL O/C)(see Figure 15.4 -

Strany 103

T400 Controller Facilities Manual667/EB/20200/000 Page 18-14 Issue 9Figure 18.8 - CONNECTING DUAL LEVEL AUDIBLESContact protectionresistor(normally 22

Strany 104

T400 Controller Facilities Manual667/EB/20200/000 Page 18-15 Issue 9Figure 18.9 - Single Sided Access T400LTELECOMSCONNECTION POSTSEE 667/GA/20287/250

Strany 105

T400 Controller Facilities Manual667/EB/20200/000 Page 18-16 Issue 9DANGERPHASE PCB(S) LOCATIONUP TO 16 PHASESCPU AND I/O PCB(S) ETCLOCATIONPOLYESTER

Strany 106

T400 Controller Facilities Manual667/EB/20200/000 Page 19-1 Issue 919. ORIGINAL LAMP MONITORING UNITThis is a separate item of hardware and is not pa

Strany 107

T400 Controller Facilities Manual667/EB/20200/000 Page 19-2 Issue 9Figure 19.1 - LAMP MONITOR OVERVIEWCurrent SensorInputsGreen Voltage InputsLamp Sup

Strany 108

T400 Controller Facilities Manual667/EB/20200/000 Page 19-3 Issue 919.1 LAMP MONITOR + OTU (NOT RED LAMP MONITORING)With the standard lamp monitoring

Strany 109

T400 Controller Facilities Manual667/EB/20200/000 Page 19-4 Issue 919.2 RED LAMP MONITORINGThis facility monitors the state of lamps at an intersecti

Strany 110

T400 Controller Facilities Manual667/EB/20200/000 Page 19-5 Issue 9NOTES (1) CLF Mode - When calculating the minimum cycle time of a CLF plan the Rede

Strany 111

T400 Controller Facilities Manual667/EB/20200/000 Page 19-6 Issue 9a) Red Lamp Monitoring on Part-Time SignalsThe LMU outputs have the following effec

Strany 112

T400 Controller Facilities Manual667/EB/20200/000 Page ii Issue 9SAFETY WARNINGIn the interests of health and safety, when using or servicing this equ

Strany 113

T400 Controller Facilities Manual667/EB/20200/000 Page 1-4 Issue 9667/HA/20200/000MAINTENANCE HANDBOOK FOR THE T400 CONTROLLERThis handbook details th

Strany 114

T400 Controller Facilities Manual667/EB/20200/000 Page 19-7 Issue 9 Case 3 - Controller making transition to the Stage whichcontains t

Strany 115

T400 Controller Facilities Manual667/EB/20200/000 Page 19-8 Issue 9Figure 19.3 - LMU Hold without losing phase delayR/AAAMBERAMBERAMBERAMBERABCDR/AR/A

Strany 116

T400 Controller Facilities Manual667/EB/20200/000 Page 19-9 Issue 9Figure 19.4 - LMU Hold with losing phase delayR/AAAMBERAMBERAMBERAMBERABCDR/AR/AR/A

Strany 117

T400 Controller Facilities Manual667/EB/20200/000 Page 19-10 Issue 919.3 L.M.U. PARALLEL STAGE STREAMING FACILITIES19.3.1 LMU Supplementary Intergre

Strany 118

T400 Controller Facilities Manual667/EB/20200/000 Page 19-11 Issue 919.4 SET UP CONNECTIONS FOR RED LAMP MONITORINGInstallation is in accordance with

Strany 119

T400 Controller Facilities Manual667/EB/20200/000 Page 19-12 Issue 919.4.4 Configuration RequirementsStarting Intergreen: A value of 8 seconds is req

Strany 120

T400 Controller Facilities Manual667/EB/20200/000 Page 20-1 Issue 920. SPECIAL CONDITIONING20.1 INTRODUCTIONThere are often special requirements for t

Strany 121

T400 Controller Facilities Manual667/EB/20200/000 Page 20-2 Issue 920.4 READING CONTROLLER TIMERSIt is possible to read whether certain controller ti

Strany 122

T400 Controller Facilities Manual667/EB/20200/000 Page 20-3 Issue 9ExampleIf a side road phase is extending towards its maximum and a demand is insert

Strany 123

T400 Controller Facilities Manual667/EB/20200/000 Page 21-1 Issue 921. EXAMPLE OF AN INTERSECTIONThis section consists of an example of an intersecti

Strany 124

T400 Controller Facilities Manual667/EB/20200/000 Page 2-1 Issue 92. STAGES2.1 FACILITIESThere are up to 16 stages (0 to 15) available for use.Stage 0

Strany 125

T400 Controller Facilities Manual667/EB/20200/000 Page 21-2 Issue 9Figure 21.1 - CUSTOMER SPEC SHEET EXAMPLE

Strany 126

T400 Controller Facilities Manual667/EB/20200/000 Page 21-3 Issue 9Figure 21.2 - CUSTOMER SPEC SHEET EXAMPLE

Strany 127

T400 Controller Facilities Manual667/EB/20200/000 Page 21-4 Issue 9Figure 21.3 - CUSTOMER SPEC SHEET EXAMPLE

Strany 128 - 12. THE EVENT TIMETABLE

T400 Controller Facilities Manual667/EB/20200/000 Page 21-5 Issue 9Figure 21.4 - CUSTOMER SPEC SHEET EXAMPLE

Strany 129

T400 Controller Facilities Manual667/EB/20200/000 Page 21-6 Issue 9Figure 21.4a - CUSTOMER SPEC SHEET EXAMPLE

Strany 130

T400 Controller Facilities Manual667/EB/20200/000 Page 21-7 Issue 9Figure 21.5 - CUSTOMER SPEC SHEET EXAMPLE

Strany 131

T400 Controller Facilities Manual667/EB/20200/000 Page 21-8 Issue 9Figure 21.6a - CUSTOMER SPEC SHEET EXAMPLE

Strany 132

T400 Controller Facilities Manual667/EB/20200/000 Page 21-9 Issue 9Figure 21.6b - CUSTOMER SPEC SHEET EXAMPLE

Strany 133

T400 Controller Facilities Manual667/EB/20200/000 Page 21-10 Issue 9Figure 21.7 - CUSTOMER SPEC SHEET EXAMPLE

Strany 134 - 13. LINKING

T400 Controller Facilities Manual667/EB/20200/000 Page 21-11 Issue 9Figure 21.8 - CUSTOMER SPEC SHEET EXAMPLE

Strany 135

T400 Controller Facilities Manual667/EB/20200/000 Page 2-2 Issue 9Firstly, the controller sets the “suggested stage” as the current stage and the numb

Strany 136

T400 Controller Facilities Manual667/EB/20200/000 Page 21-12 Issue 9Figure 21.8a - CUSTOMER SPEC SHEET EXAMPLE

Strany 137

T400 Controller Facilities Manual667/EB/20200/000 Page 21-13 Issue 9Figure 21.9 - CUSTOMER SPEC SHEET EXAMPLE

Strany 138

T400 Controller Facilities Manual667/EB/20200/000 Page 21-14 Issue 9Figure 21.9a - CUSTOMER SPEC SHEET EXAMPLE

Strany 139

T400 Controller Facilities Manual667/EB/20200/000 Page 21-15 Issue 9Figure 21.9b - CUSTOMER SPEC SHEET EXAMPLE

Strany 140

T400 Controller Facilities Manual667/EB/20200/000 Page 21-16 Issue 9Figure 21.10 - CUSTOMER SPEC SHEET EXAMPLE

Strany 141 - 15. INPUTS AND OUTPUTS

T400 Controller Facilities Manual667/EB/20200/000 Page 21-17 Issue 9Figure 21.11 - CUSTOMER SPEC SHEET EXAMPLE

Strany 142

T400 Controller Facilities Manual667/EB/20200/000 Page 21-18 Issue 9Figure 21.12 - CUSTOMER SPEC SHEET EXAMPLE

Strany 143

T400 Controller Facilities Manual667/EB/20200/000 Page 21-19 Issue 9Figure 21.13 - CUSTOMER SPEC SHEET EXAMPLE

Strany 144

T400 Controller Facilities Manual667/EB/20200/000 Page 21-20 Issue 9Figure 21.14 - CUSTOMER SPEC SHEET EXAMPLE

Strany 145 - REARFRONT

T400 Controller Facilities Manual667/EB/20200/000 Page 21-21 Issue 9Figure 21.15 - CUSTOMER SPEC SHEET EXAMPLE

Strany 146

T400 Controller Facilities Manual667/EB/20200/000 Page 2-3 Issue 9If NO, add the demand phases in this stage (or the stage itself if stage isdemanded)

Strany 147

T400 Controller Facilities Manual667/EB/20200/000 Page 21-22 Issue 9Figure 21.16 - CUSTOMER SPEC SHEET EXAMPLE

Strany 148

T400 Controller Facilities Manual667/EB/20200/000 Page 21-23 Issue 9Figure 21.17 - CUSTOMER SPEC SHEET EXAMPLE

Strany 149 - DISTRIBUTION PANEL

T400 Controller Facilities Manual667/EB/20200/000 Page 21-24 Issue 9Figure 21.18 - CUSTOMER SPEC SHEET EXAMPLE

Strany 150

T400 Controller Facilities Manual667/EB/20200/000 Page 21-25 Issue 9Figure 21.19 - CUSTOMER SPEC SHEET EXAMPLE

Strany 151

T400 Controller Facilities Manual667/EB/20200/000 Page 21-26 Issue 9Figure 21.20 - CUSTOMER SPEC SHEET EXAMPLE

Strany 152

T400 Controller Facilities Manual667/EB/20200/000 Page 21-27 Issue 9Figure 21.21 - CUSTOMER SPEC SHEET EXAMPLE

Strany 153

T400 Controller Facilities Manual667/EB/20200/000 Page 22-1 Issue 922. EXAMPLE OF AN INTERSECTION ROAD TRAFFIC & LIGHT RAILVEHICLESThis section c

Strany 154

T400 Controller Facilities Manual667/EB/20200/000 Page 22-2 Issue 9Figure 22.1 - CUSTOMER SPEC SHEET EXAMPLE

Strany 155 - 16. MANUAL PANEL

T400 Controller Facilities Manual667/EB/20200/000 Page 22-3 Issue 9Figure 22.2 - CUSTOMER SPEC SHEET EXAMPLE

Strany 156

T400 Controller Facilities Manual667/EB/20200/000 Page 22-4 Issue 9Figure 22.3 - CUSTOMER SPEC SHEET EXAMPLE

Strany 157

T400 Controller Facilities Manual667/EB/20200/000 Page 2-4 Issue 9However, in other modes, namely CLF, UTC, Fixed Time, Priority, Part-Time, Manualand

Strany 158

T400 Controller Facilities Manual667/EB/20200/000 Page 22-5 Issue 9Figure 22.4 - CUSTOMER SPEC SHEET EXAMPLE

Strany 159

T400 Controller Facilities Manual667/EB/20200/000 Page 22-6 Issue 9Figure 22.5 - CUSTOMER SPEC SHEET EXAMPLE

Strany 160 - MANUAL CONTROL

T400 Controller Facilities Manual667/EB/20200/000 Page 22-7 Issue 9Figure 22.6 - CUSTOMER SPEC SHEET EXAMPLE

Strany 161

T400 Controller Facilities Manual667/EB/20200/000 Page 22-8 Issue 9Figure 22.7 - CUSTOMER SPEC SHEET EXAMPLE

Strany 162

T400 Controller Facilities Manual667/EB/20200/000 Page 22-9 Issue 9Figure 22.8 - CUSTOMER SPEC SHEET EXAMPLE

Strany 163

T400 Controller Facilities Manual667/EB/20200/000 Page 22-10 Issue 9Figure 22.9 - CUSTOMER SPEC SHEET EXAMPLE

Strany 164

T400 Controller Facilities Manual667/EB/20200/000 Page 22-11 Issue 9Figure 22.10 - CUSTOMER SPEC SHEET EXAMPLE

Strany 165

T400 Controller Facilities Manual667/EB/20200/000 Page 22-12 Issue 9Figure 22.11 - CUSTOMER SPEC SHEET EXAMPLE

Strany 166

T400 Controller Facilities Manual667/EB/20200/000 Page 22-13 Issue 9Figure 22.12 - CUSTOMER SPEC SHEET EXAMPLE

Strany 167

T400 Controller Facilities Manual667/EB/20200/000 Page 22-14 Issue 9Figure 22.13 - CUSTOMER SPEC SHEET EXAMPLE

Strany 168

T400 Controller Facilities Manual667/EB/20200/000 Page 2-5 Issue 9All stages contained within a stream must be numbered consecutively starting at Stag

Strany 169

T400 Controller Facilities Manual667/EB/20200/000 Page 22-15 Issue 9Figure 22.14 - CUSTOMER SPEC SHEET EXAMPLE

Strany 170

T400 Controller Facilities Manual667/EB/20200/000 Page 22-16 Issue 9Figure 22.15 - CUSTOMER SPEC SHEET EXAMPLE

Strany 171

T400 Controller Facilities Manual667/EB/20200/000 Page 22-17 Issue 9Figure 22.16 - CUSTOMER SPEC SHEET EXAMPLE

Strany 172

T400 Controller Facilities Manual667/EB/20200/000 Page 22-18 Issue 9Figure 22.17 - CUSTOMER SPEC SHEET EXAMPLE

Strany 173

T400 Controller Facilities Manual667/EB/20200/000 Page 22-19 Issue 9Figure 22.18 - CUSTOMER SPEC SHEET EXAMPLE

Strany 174

T400 Controller Facilities Manual667/EB/20200/000 Page 22-20 Issue 9Figure 22.19 - CUSTOMER SPEC SHEET EXAMPLE

Strany 175

T400 Controller Facilities Manual667/EB/20200/000 Page 22-21 Issue 9Figure 22.20 - CUSTOMER SPEC SHEET EXAMPLE

Strany 176

T400 Controller Facilities Manual667/EB/20200/000 Page 22-22 Issue 9Figure 22.21 - CUSTOMER SPEC SHEET EXAMPLE

Strany 177

T400 Controller Facilities Manual667/EB/20200/000 Page 22-23 Issue 9Figure 22.22 - CUSTOMER SPEC SHEET EXAMPLE

Strany 178 - 18. EQUIPMENT

T400 Controller Facilities Manual667/EB/20200/000 Page 22-24 Issue 9Figure 22.23 - CUSTOMER SPEC SHEET EXAMPLE

Strany 179

T400 Controller Facilities Manual667/EB/20200/000 Page 2-6 Issue 92.6.4 Mode Operation(See also section 9.)2.6.4(a) Fixed TimeEach stream will have

Strany 180

T400 Controller Facilities Manual667/EB/20200/000 Page 22-25 Issue 9Figure 22.24 - CUSTOMER SPEC SHEET EXAMPLE

Strany 181

T400 Controller Facilities Manual667/EB/20200/000 Page 22-26 Issue 9Figure 22.25 - CUSTOMER SPEC SHEET EXAMPLE

Strany 182

T400 Controller Facilities Manual667/EB/20200/000 Page 22-27 Issue 9Figure 22.26 - CUSTOMER SPEC SHEET EXAMPLE

Strany 183

T400 Controller Facilities Manual667/EB/20200/000 Page 22-28 Issue 9Figure 22.27 - CUSTOMER SPEC SHEET EXAMPLE

Strany 184 - Pedestrian Signal Head

T400 Controller Facilities Manual667/EB/20200/000 Page 22-29 Issue 9Figure 22.28 - CUSTOMER SPEC SHEET EXAMPLE

Strany 185 - Controller

T400 Controller Facilities Manual667/EB/20200/000 Page 22-30 Issue 9Figure 22.29 - CUSTOMER SPEC SHEET EXAMPLE

Strany 186 - MCE0125 Pelican Signal Head

T400 Controller Facilities Manual667/EB/20200/000 Page 22-31 Issue 9Figure 22.30 - CUSTOMER SPEC SHEET EXAMPLE

Strany 187 - Signal Head

T400 Controller Facilities Manual667/EB/20200/000 Page 22-32 Issue 9Figure 22.31 - CUSTOMER SPEC SHEET EXAMPLE

Strany 188

T400 Controller Facilities Manual667/EB/20200/000 Page 22-33 Issue 9Figure 22.32 - CUSTOMER SPEC SHEET EXAMPLE

Strany 189

T400 Controller Facilities Manual667/EB/20200/000 Page 23-1 Issue 923. MOVA (MICROPROCESSOR OPTIMISED VEHICLE ACTUATION)At present, MOVA is implement

Strany 190

T400 Controller Facilities Manual667/EB/20200/000 Page 2-7 Issue 9The Awaiting New Command lamp will only illuminate when all phase minimums onall str

Strany 191

T400 Controller Facilities Manual667/EB/20200/000 Page 23-2 Issue 9However, some customers will ask for the push buttons to be wired via the UTCinterf

Strany 192 - VIEW ON SECTION AA

T400 Controller Facilities Manual667/EB/20200/000 Page 24-1 Issue 924. GAS PLINTH24.1 GENERAL DESCRIPTIONA gas plinth can be fitted below the contro

Strany 193 - COVER CLOSED

T400 Controller Facilities Manual667/EB/20200/000 Page 25-1 Issue 925. ANCILLARY PROCESSOR (Integral OTU/LMU/RLM)25.1 GENERAL DESCRIPTIONThe Ancilla

Strany 194

T400 Controller Facilities Manual667/EB/20200/000 Page 25-2 Issue 9On detection of first red lamp failure the RLM response is :-• The T400 system LED

Strany 195

T400 Controller Facilities Manual667/EB/20200/000 Page 25-3 Issue 9Red Lamp Monitor Operation1. The voltage monitor transformer measures the actual vo

Strany 196

T400 Controller Facilities Manual667/EB/20200/000 Page 25-4 Issue 925.1.2 PHYSICAL DESCRIPTION25.1.2(a) Mechanical ConstructionThe PCB is located wi

Strany 197

T400 Controller Facilities Manual667/EB/20200/000 Page 25-5 Issue 925.2 ANCILLARY PROCESSOR CARD INSTALLATION25.2.1 GeneralInstallation and commissi

Strany 198

T400 Controller Facilities Manual667/EB/20200/000 Page 25-6 Issue 925.2.4 CoverThe PCB is fitted with a cover (part number 667/2/25192/000 front, 667

Strany 199

T400 Controller Facilities Manual667/EB/20200/000 Page 25-7 Issue 94. S4 - 600 Ohm/High Impedance SwitchSwitch S4 - Installation(To be performed by qu

Strany 200

T400 Controller Facilities Manual667/EB/20200/000 Page 25-8 Issue 9Figure 25.1 - Ancillary Processor PCB LayoutONS1 - 2/4 Wire SelectorS4 - 600Ω / Hig

Strany 201

T400 Controller Facilities Manual667/EB/20200/000 Page 2-8 Issue 9Each stream will then move immediately to its individual switch off stage subject to

Strany 202

T400 Controller Facilities Manual667/EB/20200/000 Page 25-9 Issue 925.2.6 Connectors and Cables25.2.6(a) Extended System Bus Ribbon CableConnect the

Strany 203

T400 Controller Facilities Manual667/EB/20200/000 Page 25-10 Issue 9Figure 25.2 - LMU Input ConnectorPLB Pin Name Berg Pin PLB Pin Name Berg Pin1 Sens

Strany 204

T400 Controller Facilities Manual667/EB/20200/000 Page 25-11 Issue 9Current TransformersEach controller phase or illuminated indicator that is to be m

Strany 205

T400 Controller Facilities Manual667/EB/20200/000 Page 25-12 Issue 9If the nominal load current (excluding red/ambers) of a particular controlleroutpu

Strany 206 - 20. SPECIAL CONDITIONING

T400 Controller Facilities Manual667/EB/20200/000 Page 25-13 Issue 9current sensors should then be anchored by passing a TYWRAP or equivalent throught

Strany 207

T400 Controller Facilities Manual667/EB/20200/000 Page 25-14 Issue 925.2.7 Effect of Incorrect Switch Settings on the Ancillary Processor PCB (i) S

Strany 208

T400 Controller Facilities Manual667/EB/20200/000 Page 25-15 Issue 925.2.8 Fault Finding at the OutstationSymptom Possible ReasonSystem Fault LED lit

Strany 209

T400 Controller Facilities Manual667/EB/20200/000 Page 25-16 Issue 925.3 RLM GENERAL DESCRIPTION25.3.1 Background InformationThe RLM facility is re

Strany 210

T400 Controller Facilities Manual667/EB/20200/000 Page 25-17 Issue 925.4 ENHANCED RLM DETAILED DESCRIPTIONIn descriptions below, references (C1), (C2

Strany 211

T400 Controller Facilities Manual667/EB/20200/000 Page 25-18 Issue 9For demand dependent phases gaining right-of-way when the RLF1 indication isalread

Strany 212

T400 Controller Facilities Manual667/EB/20200/000 Page 2-9 Issue 9intergreens on the configured stage to stage movements will be held until thesupplem

Strany 213

T400 Controller Facilities Manual667/EB/20200/000 Page 25-19 Issue 925.4.2 Operation On Second Red Lamp FailThe operation of the controller when a se

Strany 214

T400 Controller Facilities Manual667/EB/20200/000 Page 25-20 Issue 925.4.2(a) Configuration OptionsThe effect of a second red lamp fail on the RLM de

Strany 215

T400 Controller Facilities Manual667/EB/20200/000 Page 25-21 Issue 9Only the ‘non-latching’ mode of operation is available on the controller when usin

Strany 216

T400 Controller Facilities Manual667/EB/20200/000 Page 25-22 Issue 925.4.5 Configuration Data(C1) RLM Delayed Phases (PROM item - RLMDFZ)This is an 8

Strany 217

T400 Controller Facilities Manual667/EB/20200/000 Page 25-23 Issue 9(C4) RLF2 Cancel Option (PROM item - RLF2_CANCEL_RLF1)This byte contains one bit f

Strany 218

T400 Controller Facilities Manual667/EB/20200/000 Page 25-24 Issue 9(C7) RLM Phase Delay Times (PROM item - RLMBUV & RAM item - RLMTME)This 16 byt

Strany 219

T400 Controller Facilities Manual667/EB/20200/000 Page 25-25 Issue 9(C12) LMU Moves Array (PROM item - LMUMOV)This is an existing config PROM item whi

Strany 220

T400 Controller Facilities Manual667/EB/20200/000 Page A-1 Issue 9APPENDIX A) SUPPLYING DC POWER FOR VEHICLE DETECTORSTable APPENDIX A) -1 gives the

Strany 221

T400 Controller Facilities Manual667/EB/20200/000 Page A-2 Issue 9Appendix APPENDIX A) .1) Using 24v 2A Internal Supply for DetectorsThere is spare ca

Strany 222

T400 Controller Facilities Manual667/EB/20200/000 Page A-3 Issue 9Appendix APPENDIX A) .2) Using 24v 2A Internal Supply - Cable limitationsTable APPEN

Strany 223

T400 Controller Facilities Manual667/EB/20200/000 Page iii Issue 9ISSUE HISTORYDOCUMENT ISSUE: 8PAGES ISSUE PAGES ISSUE PAGES ISSUEi to xvi 9 10-1 to

Strany 224

T400 Controller Facilities Manual667/EB/20200/000 Page 3-1 Issue 93. PHASES3.1 FACILITIESThere are up to 16 phases (A to P) available for use as any o

Strany 225

T400 Controller Facilities Manual667/EB/20200/000 Page A-4 Issue 9Table APPENDIX A) -4) Number of Detector Boards (SarasotaMTS38Z/36Z/35Z) in External

Strany 226

T400 Controller Facilities Manual667/EB/20200/000 Page A-5 Issue 9Appendix APPENDIX A) .3) Using 27.5v Additional Detector PSUWhere there is insuffici

Strany 227

T400 Controller Facilities Manual667/EB/20200/000 Page A-6 Issue 9Appendix APPENDIX A) .4) Using 27.5v Detector Supply - Cable LimitationsTable APPEND

Strany 228

T400 Controller Facilities Manual667/EB/20200/000 Page A-7 Issue 9Table APPENDIX A) -11) Number of Detector Boards (Sarasota) in ExternalHousing(s) Us

Strany 229

T400 Controller Facilities Manual667/EB/20200/000 Page A-8 Issue 9Appendix APPENDIX A) .5) Cable Distances for SDENOTE: SDE/SA cabling assumes the use

Strany 230

T400 Controller Facilities Manual667/EB/20200/000 Page A-9 Issue 9Table APPENDIX A) -14) Cable Distances for SDE using Sarasota Detectors (2CHANNEL)Ca

Strany 231

T400 Controller Facilities Manual667/EB/20200/000 Page A-10 Issue 9Table APPENDIX A) -15) Maximum Distances for feeder cable when using ‘D’DetectorsLo

Strany 232

T400 Controller Facilities Manual667/EB/20200/000 Page B-1 Issue 9APPENDIX B) 50-0-50 Volt ControllerB.1 50-0-50 volt ControllerNote: This version of

Strany 233

T400 Controller Facilities Manual667/EB/20200/000 Page B-2 Issue 9B.2 Dual Solar Cell (Only Available on 50-0-50 Volt Controller)The solar cell facili

Strany 234

T400 Controller Facilities Manual667/EB/20200/000 Page 3-2 Issue 9The red/amber period is normally 2 seconds and the amber period is normally 3seconds

Strany 235

T400 Controller Facilities Manual667/EB/20200/000 Page 3-3 Issue 93.2.2(b) MCE0141 Audible Indication 2 (High Voltage)The audible signals are driven

Strany 236 - VEHICLES

T400 Controller Facilities Manual667/EB/20200/000 Page 3-4 Issue 9green arrow that appears unconditionally must always be followed by its associatedph

Strany 237

T400 Controller Facilities Manual667/EB/20200/000 Page 3-5 Issue 9The normal functions of a switched sign phase are as follows:3.2.5(a) Secret Regula

Strany 238

T400 Controller Facilities Manual667/EB/20200/000 Page 3-6 Issue 9All phases will normally be set to oppose each other, unless works specifications fo

Strany 239

T400 Controller Facilities Manual667/EB/20200/000 Page 3-7 Issue 93.5.3 Maximum Green (MAX,MBX,MCX,MDX)A maximum green timer is provided for each veh

Strany 240

T400 Controller Facilities Manual667/EB/20200/000 Page 3-8 Issue 9No intergreen period is reduced below its value during phase changes. In the event o

Strany 241

T400 Controller Facilities Manual667/EB/20200/000 Page 3-9 Issue 9(i) Fixed Period during Manual Step-On. (Export only).The timing range is 0 to 255 s

Strany 242

T400 Controller Facilities Manual667/EB/20200/000 Page 3-10 Issue 93.6.1 Minimum Green ThresholdsMinimum Green times have range limits for each phase

Strany 243

T400 Controller Facilities Manual667/EB/20200/000 Page iv Issue 9SUMMARY OF SECTIONS1. INTRODUCTION2. STAGES3. PHASES4. DEMANDS AND EXTENSIONS5. CALL/

Strany 244

T400 Controller Facilities Manual667/EB/20200/000 Page 3-11 Issue 93.7.3 Appearance Type 2The phase will only appear whenever its associated stage ru

Strany 245

T400 Controller Facilities Manual667/EB/20200/000 Page 3-12 Issue 9(ii) The conditional phase is programmed as an Appearance Type 2 andconditioning ti

Strany 246

T400 Controller Facilities Manual667/EB/20200/000 Page 3-13 Issue 9c) be demand dependant3.10 CONDITIONS OF TERMINATION3.10.1 Termination Type 0The

Strany 247

T400 Controller Facilities Manual667/EB/20200/000 Page 4-1 Issue 94. DEMANDS AND EXTENSIONS4.1 GENERAL DESCRIPTIONDemands may be inserted for phases

Strany 248

T400 Controller Facilities Manual667/EB/20200/000 Page 4-2 Issue 94.3.3 Revertive DemandsWhen a vehicle actuated phase terminates with an extension a

Strany 249

T400 Controller Facilities Manual667/EB/20200/000 Page 4-3 Issue 94.4 OPERATION DURING CERTAIN MODES4.4.1 Manual, Fixed Time and Start Up ModeDuring

Strany 250

T400 Controller Facilities Manual667/EB/20200/000 Page 5-1 Issue 95. CALL/CANCEL5.1 GENERALThere are up to 8 call/cancel units (0 to 7) available whic

Strany 251

T400 Controller Facilities Manual667/EB/20200/000 Page 6-1 Issue 96. HIGH SPEED VEHICLE DETECTIONTo provide this facility, an SDE/SA processor PCB an

Strany 252

T400 Controller Facilities Manual667/EB/20200/000 Page 6-2 Issue 96.1.3 SDE Extension InhibitAn SDE extension may be suppressed, but not the associat

Strany 253

T400 Controller Facilities Manual667/EB/20200/000 Page 6-3 Issue 9The condition in (c) is normally disabled for individual phases at the time ofconfig

Strany 254

T400 Controller Facilities Manual667/EB/20200/000 Page v Issue 9CONTENTS1. INTRODUCTION...

Strany 255

T400 Controller Facilities Manual667/EB/20200/000 Page 6-4 Issue 96.8 OTHER LOOP SPACINGSThe SDE/SA facility can be configured to operate with 10 ft.

Strany 256

T400 Controller Facilities Manual667/EB/20200/000 Page 6-5 Issue 9Figure 6.1 - SDE/SA LAYOUTS(c) Speed Assessment151m91m159m79mStopLine12’(3.66m)(a) D

Strany 257

T400 Controller Facilities Manual667/EB/20200/000 Page 7-1 Issue 97. ALL-RED DISPLAYSThere are two methods of achieving an all-red display:- All-re

Strany 258

T400 Controller Facilities Manual667/EB/20200/000 Page 7-2 Issue 97.2 RED EXTENSION DURING INTERGREENThe occupation of an All Red detector loop durin

Strany 259

T400 Controller Facilities Manual667/EB/20200/000 Page 7-3 Issue 9Stage movements for all red units are specified as follows:Unit 7 1 - 2Unit 6 1 - 3U

Strany 260

T400 Controller Facilities Manual667/EB/20200/000 Page 7-4 Issue 9NB Care must be taken when using/testing independent intergreens. The Extend AllRe

Strany 261

T400 Controller Facilities Manual667/EB/20200/000 Page 8-1 Issue 98. PHASE DELAYS8.1 GENERAL DESCRIPTIONIn order to gain more efficient use of phases

Strany 262

T400 Controller Facilities Manual667/EB/20200/000 Page 8-2 Issue 9Figure 8.1 - DELAY PHASE LOSING RIGHT-OF-WAYGREEN...GREENAAMBERAMBERBR/AR/AEF...S

Strany 263

T400 Controller Facilities Manual667/EB/20200/000 Page 8-3 Issue 98.3 PHASES GAINING RIGHT-OF-WAYThe intergreen times from a conflicting phase determ

Strany 264

T400 Controller Facilities Manual667/EB/20200/000 Page 8-4 Issue 98.5 PHASE DELAY HANDSET COMMANDSThere are three handset commands which can be used

Strany 265

T400 Controller Facilities Manual667/EB/20200/000 Page vi Issue 93.6.1 Minimum Green Thresholds ...

Strany 266

T400 Controller Facilities Manual667/EB/20200/000 Page 8-5 Issue 9Figure 8.2 - DELAY PHASE GAINING RIGHT-OF-WAYGREEN...GREENEAMBERAR/AR/AGB...Stage

Strany 267

T400 Controller Facilities Manual667/EB/20200/000 Page 9-1 Issue 99. MODESThe following modes are available: (a) Fixed Time (FT) (b) Vehicle Actua

Strany 268

T400 Controller Facilities Manual667/EB/20200/000 Page 9-2 Issue 9With the mode priorities defined, the controller adopts the highest priority mode fo

Strany 269

T400 Controller Facilities Manual667/EB/20200/000 Page 9-3 Issue 9(b) Amber Leaving/Red Display.Following the blackout an amber leaving signal is show

Strany 270

T400 Controller Facilities Manual667/EB/20200/000 Page 9-4 Issue 9Figure 9.1 - START-UP SEQUENCE BLACK-OUT BLACK-OUT BLACK-OUT BLACK-OUT BLACK-OUTREDR

Strany 271 - 24. GAS PLINTH

T400 Controller Facilities Manual667/EB/20200/000 Page 9-5 Issue 99.2 PART TIME MODEDuring part-time mode, normal traffic control operations are susp

Strany 272

T400 Controller Facilities Manual667/EB/20200/000 Page 9-6 Issue 99.3 URBAN TRAFFIC CONTROL (UTC) MODE(Normally an O.T.U. is required for this facili

Strany 273

T400 Controller Facilities Manual667/EB/20200/000 Page 9-7 Issue 99.3.2 Summary of Control and Reply BitsControl BitsSection Bit designation Title(a)

Strany 274

T400 Controller Facilities Manual667/EB/20200/000 Page 9-8 Issue 99.3.3 Control BitsSee Figure 21.149.3.3(a) Demands - Common (DX) and Stage (D1,D2

Strany 275

T400 Controller Facilities Manual667/EB/20200/000 Page 9-9 Issue 99.3.3(c) Switch Facility (SF1 and SF2)An ‘SF’ bit may be programmed to simulate any

Strany 276

T400 Controller Facilities Manual667/EB/20200/000 Page vii Issue 96.5 SDE/SA PARALLEL STAGE STREAMING FACILITIES ... 6-

Strany 277

T400 Controller Facilities Manual667/EB/20200/000 Page 9-10 Issue 99.3.3(i) Take Over (TO)A ‘TO’ bit may be programmed so that no ‘F’ bits will be ef

Strany 278

T400 Controller Facilities Manual667/EB/20200/000 Page 9-11 Issue 9sets the seconds to 30 (and the sub-seconds counter to 0). The hour is disregarded

Strany 279 - Push down this

T400 Controller Facilities Manual667/EB/20200/000 Page 9-12 Issue 9When ‘G1/G2’ is received at the central office the computer releases controlimmedia

Strany 280

T400 Controller Facilities Manual667/EB/20200/000 Page 9-13 Issue 99.3.4(e) CLF Group Synchronisation Confirm (CS)A ‘CS’ bit may be returned to confi

Strany 281

T400 Controller Facilities Manual667/EB/20200/000 Page 9-14 Issue 9Figure 21.15 indicates where to request the conditions required. In the example sho

Strany 282

T400 Controller Facilities Manual667/EB/20200/000 Page 9-15 Issue 99.3.4(o) Solar Override Confirm (SC)An ‘SC’ reply bit may be returned to indicate

Strany 283

T400 Controller Facilities Manual667/EB/20200/000 Page 9-16 Issue 9A ‘PX’ bit simulates a pedestrian demand.(b) Hold Vehicle Stage (PV)A ‘PV’ bit hold

Strany 284

T400 Controller Facilities Manual667/EB/20200/000 Page 9-17 Issue 9The above conditions may not cause UTC mode to become the current mode due tothe mo

Strany 285

T400 Controller Facilities Manual667/EB/20200/000 Page 9-18 Issue 9am and the real Introduction time of the Plan. The controller then brings the C.L.F

Strany 286

T400 Controller Facilities Manual667/EB/20200/000 Page 9-19 Issue 99.4 PRIORITY AND EMERGENCY VEHICLE MODEPriority and Emergency Vehicle modes provid

Strany 287

T400 Controller Facilities Manual667/EB/20200/000 Page viii Issue 99.5 HURRY CALL MODE ...

Strany 288

T400 Controller Facilities Manual667/EB/20200/000 Page 9-20 Issue 99.4.1(b) Priority ExtensionA continuation of a green signal requested by vehicle(s

Strany 289

T400 Controller Facilities Manual667/EB/20200/000 Page 9-21 Issue 99.4.2 Operational Description9.4.2(a) GeneralUnder no circumstances will the intr

Strany 290

T400 Controller Facilities Manual667/EB/20200/000 Page 9-22 Issue 99.4.2(b) Precedence LevelsFor isolated operation, the normal order of precedence f

Strany 291

T400 Controller Facilities Manual667/EB/20200/000 Page 9-23 Issue 9When the inhibit period is not specified, then irrespective of the normal cyclic st

Strany 292

T400 Controller Facilities Manual667/EB/20200/000 Page 9-24 Issue 9A compensation period will only be introduced on a particular running phase if ther

Strany 293

T400 Controller Facilities Manual667/EB/20200/000 Page 9-25 Issue 9When a priority change from the bus priority level to the emergency vehicle priorit

Strany 294

T400 Controller Facilities Manual667/EB/20200/000 Page 9-26 Issue 99.4.3 Basic FacilitiesReference should be made to Figure 21.16.Both Priority and E

Strany 295

T400 Controller Facilities Manual667/EB/20200/000 Page 9-27 Issue 99.4.3(e) Priority Units Inhibited (Priority Mode Only)When a Priority Phase gains

Strany 296

T400 Controller Facilities Manual667/EB/20200/000 Page 9-28 Issue 9(1) Priority Mode Fault MonitorWhen the input becomes active the Monitor Timer is

Strany 297

T400 Controller Facilities Manual667/EB/20200/000 Page 9-29 Issue 99.4.4 Visual IndicationsA separate indicating light emitting source is normally pr

Strany 298

T400 Controller Facilities Manual667/EB/20200/000 Page ix Issue 911.3 TIMETABLE RESOLUTION ...

Strany 299

T400 Controller Facilities Manual667/EB/20200/000 Page 9-30 Issue 99.4.6 Use of Priority Mode for Control in Light Rail Transit SystemsShown in Figur

Strany 300

T400 Controller Facilities Manual667/EB/20200/000 Page 9-31 Issue 99.4.6(b) Request DelaysThe first delay as indicated allows for the travelling time

Strany 301

T400 Controller Facilities Manual667/EB/20200/000 Page 9-32 Issue 9Figure 9.2 - PRIORITY DEMAND ORDERUSED IN SPECIALCONDITIONING TO PREVENTCERTAIN STA

Strany 302

T400 Controller Facilities Manual667/EB/20200/000 Page 9-33 Issue 99.5 HURRY CALL MODEA hurry call demand gives precedence to a particular stage to e

Strany 303

T400 Controller Facilities Manual667/EB/20200/000 Page 9-34 Issue 9hurry call is valid provided its prevent timer is not active due to a previous hurr

Strany 304 - Stop Line

T400 Controller Facilities Manual667/EB/20200/000 Page 9-35 Issue 9The reasons for a request being rejected may be: (i) The prevent timer being acti

Strany 305

T400 Controller Facilities Manual667/EB/20200/000 Page 9-36 Issue 99.5.3 Control From A Remote PushbuttonIf, on pressing the hurry request button, th

Strany 306

T400 Controller Facilities Manual667/EB/20200/000 Page 9-37 Issue 99.6 SELECTED MANUAL CONTROL MODERefer also to Section 16.MANUAL mode selected on t

Strany 307

T400 Controller Facilities Manual667/EB/20200/000 Page 9-38 Issue 9so. Where parallel stage streaming is employed the indicator will illuminate when t

Strany 308

T400 Controller Facilities Manual667/EB/20200/000 Page 9-39 Issue 99.7 MANUAL STEP-ON MODEA Manual Step-on facility can be provided when a Police Man