Connection
5.1 Lightning protection, power supply and grounding
SCALANCE W760/W720
18 Operating Instructions, 03/2015, C79000-G8976-C322-04
Supply voltage
WARNING
Safety extra low voltage
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS (Limited Power Source) complying with IEC 60950-1 / EN
60950-1 / VDE 0805-1 must be connected to the power supply terminals or the power
supply unit for the equipment power supply must comply with NEC Class 2, as described b
y
the National Electrical Code (r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
WARNING
Transient overvoltages
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).