Communication for the open mindedSiemens Enterprise CommunicationsDocumentationOpenScape Voice, Sylantro, BroadsoftoptiPoint 410/420 advance S V7.0opt
HowTo handle internal phone traces on optiPoint 410/420 S10• Copy all content between the grey Buttons into a text-file. • Save it to your computer, u
HowTo handle internal phone traces on optiPoint 410/420 S11Deactivate internal phone traces • Log-in to the WBM as administrator (see Æ page 15)• Sele
optiPoint SIP UDP Trace12optiPoint SIP UDP TraceIf problems in operating the optiPoint 410/420 S phones are encountered, showing a display message lik
optiPoint SIP UDP Trace13Once tracing is complete the SIP log can be viewed as indicated on the above screen shot by clicking on the word here.The mes
Web Interface14Web InterfaceEstablishing the Connection to the PhoneYou can display and configure device and network information for the optiPoint 410
Web Interface15A screen like the following home page appears:Access to the Web Interface Administrator MenuThe following steps describe the access to
Web Interface16Administrations Menu Administrator menu Fault InvestigationzGeneral InformationzTrace ConfigurationzNetwork IP and RoutingzTrace ViewzS
Web Interface17Additional Web Pages for Tests and TracingThe web menus relevant for tests and tracing are listed below. If you click on one of the men
Web Interface18User-assisted testsoptiPoint 410/420 standard/advanceoptiPoint 410/420 economy/economy plus and optiPoint 410 entryNot used withoptiPoi
Web Interface19RTP Statistics These parameters are used for development only.
Safety Precautions2Safety PrecautionsImportant Notes• This equipment has been tested and found to comply with the limits for a Class B digital device,
Web Interface20QoS Data CollectionThese parameters are used for development only.
Web Interface21Session data Æ page 20
Web Interface22Fault InvestigationAvailable tracing menus (selected in “Administrations Menu” on page 16:• “Trace Configuration” on page 23• “Trace Vi
Web Interface23Trace Configuration Trace Configuration is used to inform the phone of which information is to be logged.
Web Interface24Trace View Trace View is used to retrieve trace information from the phone.Simplified trace page It is a simple interface for the user
Web Interface25FTP Client To use the FTP client you will need the "Host", "username" and "password" of your FTP server a
Web Interface26Windview Configuration SIP UDP Trace
Alphabetical Reference27Alphabetical ReferenceThis reference offers basic information that can be used by the administra-tor to carry out administrati
Alphabetical Reference28Key test• Test to check the functions of the telephone keys.• If you press a key on the optiPoint 410/420 family S V7.0 (excep
Alphabetical Reference29Line Monitor information optiPoint 420LAN Port 1 (LAN)LAN Port 2 (PC)Explanation report: Æ page 18Ping• Run this Æ PING test t
Safety Precautions3An obligation to provide the respective performance features only exists if expressly agreed in the terms of contract.Location of t
Alphabetical Reference30QDC Port Enter port address of the Quality Data Collection Server. For more informa-tion refer to HiPath QoS Data Collection V
Alphabetical Reference31Trace Easy Automatic Clear Before StartWhen it is clicked in, the loggings are cleared every start, when it is not clicked you
Alphabetical Reference32Trace Easy Reset SettingsSet parameters to default values. Æ page 24Trace Easy Stop loggingStops the current logging action. Æ
Alphabetical Reference33Trace FTP Client DownloadTo put files on to the phone fill in the "Host", "username" and "password&qu
Alphabetical Reference34– Indication of input messages from device drivers/device interfaces– Indication of output messages to device drivers or dev
Alphabetical Reference35Trace StreamslIt should be noted again that performance of the phone can be seriously affected, and trace messages lost, if to
Alphabetical Reference36details on the PC, and the selected initialisation method for the com-munications path, may require that both elements are als
Alphabetical Reference37al) or WSP (binary). If the connection is by HTTP then the administrator may optionally configure a proxy address. If the conn
Alphabetical Reference38Trace View SourceThe "Trace Source" drop down box is used to tell the phone whether to re-trieve the trace informati
Alphabetical Reference39All files are stored in the directory "/tffs0/tracing". The file names are based on the name of the log being create
Safety Precautions4LabelsThe device conforms to the EU guideline 1999/5/EG, as at-tested by the CE mark.This device has been manufactured in accordanc
Alphabetical Reference40Abbreviations and Specialized TermsYou will find more information in the relevant literature on the Network Technology and Æ V
Alphabetical Reference41G.729Audio protocol for compressed voice transmission. The quality is worse than in Æ G.711 and better than in Æ G.723. Uses a
Alphabetical Reference42LDAPAbbreviation for "Lightweight Directory Access Protocol". Simplified protocol for accessing standardized directo
Alphabetical Reference43RTCPAbbreviation for "Realtime Transport Control Protocol".RTPAbbreviation for "Realtime Transport Protocol&quo
Alphabetical Reference44TCPAbbreviation for "Transmission Control Protocol".TLSAbbreviation for "Transport Layer Security".This pr
45IndexIndexAAbbreviations ... 40Audio loop test ... 27CConformity
© Siemens Enterprise Communications GmbH & Co. KGHofmannstr. 51,D-81359 MünchenThe information provided in this document contains merely general d
5ContentsContentsSafety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2HowTo handle internal phone traces on optiPoint 410/420
6ContentsAlphabetical Reference . . . . . . . . . . . . . . . . . . . . . . .27Description of Functions . . . . . . . . . . . . . . . . . . . . . . .
HowTo handle internal phone traces on optiPoint 410/420 S7HowTo handle internal phone traces on optiPoint 410/420 STrace Configuration is used to info
HowTo handle internal phone traces on optiPoint 410/420 S8Activate internal phone traces• Log-in to the WBM as administrator (see Æ page 15)• Select t
HowTo handle internal phone traces on optiPoint 410/420 S9Trace logging is now activated and all relevant activities of the phone will be saved (till
Komentáře k této Příručce