AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202 Page 35 of 120 27.04.2006
VEXT
See note 1
TXD0/TXD1/RTS0/RTS1/DTR0 (driven by the application)
Interface pins
Undefined
Defined
PWR_IND
CTS0/CTS1/DSR0/DTR0
Figure 8: Signal states during turn-off procedure
Note 1: Depending on capacitance load from host application
3.3.3.2 Leakage Current in Power-Down Mode
The leakage current in Power-down mode varies depending on the following conditions:
If the supply voltage at BATT+ was disconnected and then applied again without starting
up the AC75 module, the leakage current ranges between 90µA and 100µA.
If the AC75 module is started and afterwards powered down with AT^SMSO, then the
leakage current is only 50µA.
Therefore, in order to minimize the leakage current take care to start up the module at least
once before it is powered down.