Version V1.0 Page 61
Copyright (C) Siemens AG 2000. All rights reserved. 12/00
7.5.2.4 Interface Signals
Pin Name Signal Name Input=I
Output=O
Comment
TXD_TXS
RXD_RXS
RTS_TXE
XCTS_RXA
TxS (TxS_IM)
RxS (RxS_IM)
TxE
RxA
O
I
O
I
Send signal
(for asyn. physics TxD)
Receive signal
(for asyn. physics RxD)
Enable of the send drivers/addition signal
(for asyn. physics
RTS)
Auxiliary signal for receive
(has not been needed so far in the syn. physics unit (apply to GND); for
asyn. physics XCTS)
Figure 7.5-12:
Synchronous PROFIBUS Interface of the DPC31
In the test mode, all outputs are switched to high resistance.
7.6 DPS Watchdog Timer
7.7 Watchdog Timer
7.7.1 Automatic Baudrate Detection
The DPC31 is able to recognize the baudrate automatically. The “Baud_Search” mode is entered after each
RESET as well as after the expiration of the Watchdog(WD) timer in the ‘Baud_Control’ mode.
The DPC31 starts the search for the set baudrate always with the highest baudrate. If during the monitoring
time no SD1, SD2, or SD3 message has been received completely and faultlessly, the search is continued
with the next lower baudrate.
After detecting the correct baudrate, the DPC31 switches to the “Baud_Control” mode and monitors the
baudrate. The monitoring time can be parameterized (WD_Baud_Control_Val). The watchdog processes in
this case with a clock of 100 Hz (10 msec). Each faultlessly received message to its own station address
resets the watchdog. If the timer expires, the DPC31 reswitches to the Baud_Search mode.
7.7.2 Baudrate Monitoring
In ‘Baud_Control’, the baudrate that was found is monitored
continuously
. With each faultless address to
the DPC31s own station address, the watchdog is reset. The monitoring time is the result of multiplying
‘WD_Baud_Control_Val’ (to be parameterized by the user) by the time base (10 ms). If the monitoring time
expires, the WD_SM reenters ‘Baud_Search’. If the user handles
the DP protocol with the DPC31
(DP_Mode =1; refer to Mode Register 0), the watchdog is used for the ‘DP_Control’ mode after a ‘Set_Param
message’ with enabled response monitoring ‘WD_On = 1’ was received. If the master monitoring ‘WD_On =
0’ is switched off, the watchdog timer remains in the baudrate monitoring mode. The PROFIBUS DP state
machine is not reset if the timer expires; that is, the slave remains in the DATA_EXchange mode.