Siemens TC35 Terminal Specifikace Strana 108

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 439
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 107
TC35i AT Command Set
4.12 AT^STPB
s
m
obil
e
TC35i_ATC_V02.07 Page 108 of 439 1/30/04
Confidential / Released
Parameter Description
0
(&F)
The parity bit will not be transmitted over the air and will be replaced with 0.
This mode is the default setting if 7E1 or 7O1 is activated with
AT+ICF.
1 In a data connection 8 bits will be transmitted, including the parity bit, i.e. the
parity bit will be properly transmitted over the air. The setting shall be used if
problems are encountered when TC35i is running in the default 7E1 or 7O1
mode enabled with
AT+ICF. In this case, AT^STPB=1 shall be set in addition
to the 7E1 or 7O1 settings selected with
AT+ICF.
<n>
(num)(&W)
Zobrazit stránku 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 438 439

Komentáře k této Příručce

Žádné komentáře