Setting, Unsetting, and Restoring the System
12
Siemens Building Technologies
Fire Safety & Security Products 09.2008
5.2 Setting the System: PARTSET A
The PARTSET A option provides the following functionality:
z Perimeter protection to a building while
allowing free movement through the exit and
access areas.
z Exclusion of EXCLUDE A zones from
protection
z Instant activation of alarm on selection of
mode; by default there are no exit times
associated with PARTSET A
To select PARTSET A, enter a valid user code, scroll to the PARTSET A option
and press SELECT (right soft key).
If the alarm fails to set, see Section
5.4.
5.3 Setting the System: PARTSET B
The PARTSET B option provides the following functionality:
z Perimeter protection to a building while
allowing free movement through the exit and
access areas.
z Exclusion of EXCLUDE B zones from
protection
z Instant activation of alarm on selection of
mode; by default there are no exit times
associated with PARTSET B
To select PARTSET B, enter a valid user code, scroll to the PARTSET B option
and press SELECT (right soft key).
If the alarm fails to set, see section
5.4.
NOTE
Partset A and Partset B configuration modes are dependent upon the system has been programmed.
5.4 Failing to Set the System
The system fails to set if there is an open or fault condition detected on an alarm
zone when the FULLSET or PARTSET A/B option is selected. The Keypad
displays the zone number and description.
To set the system, locate the zone and close or fix the fault. Repeat the FULLSET
or PARTSET A/B operation.
…PARTSET A?...
EXIT SELECT
18/06/2008 12:30
PARTSET A SET
…PARTSET B?...
EXIT SELECT
18/06/2008 12:30
PARTSET B SET