Siemens IC60 Uživatelský manuál Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
Overview system technology
Sintony 60 Compact Sintony 60 Modular
Inputs and outputs
Inputs (programmable) 8 (16 zones by doubling) 8 (16 zones by doubling)
Outputs( programmable)
4(+4 with IR06-04) 4(+4 with IR06-04)
- Open collector 12V / 1A 2 3
- Relay 24V / 2A 1 1
- Internal Piezo output (No-1) 1 none
- Relay 24V/1A (IR06-04 x 1) 4 4
Functions
Independent alarm wards 2 2
Activation wards
Physical input types (freely selectable for each input) 8 + tamper 8 + tamper
Event memory with time stamp and additional information 512 512
PINs for users / installer 100 / 1 100 / 1
Weekly calendar 8 8
Local PC connection (RS232) with cable IA6-1 with cable IA6-1
Remote maintenance and configuration yes yes
Plain text programming using control unit or PC yes yes
Keypads
LCD keypads IKP6-01 IKP6-01
Activation without code yes yes
Plain text user support yes yes
Separate alarm/event buttons (fire/police/medical) yes yes
System control unit yes yes
Room temperature indication yes yes
Communication
Analog PSTN dialing device built in built in
Digital ISDN dialing device external filter necessary external filter necessary
Voice alarm via telephone IAV6-90 IAV6-90
System control via telephone yes yes
Multiple alarm protocol transfer SIA,CID,Voice,4+2 etc. SIA,CID,Voice,4+2 etc.
Backup telephone line GSM IGS6-10 IGS6-10
Line extensions
4 Input module (max. 2/control panel) IZE6-04 IZE6-04
4 Output module (max. 1/ control panel) IR06-04 IR06-04
Power supplies
Integrated power supply 1 1
External power supplies no no
Output load of the monitored power supplies (nominal voltage 12V) 0.8 A 0.8 A
Fused 12V outputs 3 3
Battery and network monitoring yes yes
Battery cut off to protect against battery damage yes yes
Sabotage monitoring yes yes
Installation of additional modules possible yes yes
Audio and video functions
verification zone 1
Call-back yes yes
2-way audio for alarm verification and intervention IAV6-90 no
Video alarm verification with image storage end of 2006 end of 2006
Remote help (audio support) yes no
Wireless
SiWay™ wireless detectors (complete product range) yes yes
SiWay™ wireless input module yes IMKW6 yes IMKW6
SiWay™ wireless remote controls yes yes
Additional external receiver (max. 2/control panel) yes yes
Dynamic battery checking yes yes
Indication of battery low in advance yes all devices yes all devices
Monitoring of frequency blocking yes yes
Detector supervision adjustable 0-99 min 0-99 min
Unidirectional wireless system yes yes
Zobrazit stránku 5