SCM-8 Switch Control The SCM-8 contains eight switches and eight pairs of LEDs.
Each pair contains one bi-color (red/green) and one yellow
LED. The functions of the switches and LEDs are pro-
grammed using the Zeus Tool (Refer to the Zeus Quick Start
Guide, P/N 315-033875). All LEDs can be programmed ON,
OFF, or FLASHING. The SCM is used for manual control of the
fire systems.
SIM-16 Supervised Input The SIM-16 is a remotely located, general purpose input module. It
provides sixteen input circuits for remote system monitoring. Each
input can be individually programmed as supervised (dry contacts only)
or unsupervised (general-purpose input). The SIM-16 has two Form C
relays. The relays and the inputs are programmable using the Zeus
programming tool.
SSD System Status Display The SSD displays the event status of a system remotely from the PMI.
It has four 40 character alphanumeric LCD character lines,
backlit upon status change or display toggling. This module
is supervised by the main panel and also has LEDs and an
optional sounder to indicate the status of the system. The
SSD has the capability to store up to 1500 event messages
and has pushbuttons to scroll through these events. Its
display is independent from the display on the PMI and
during the SSD initial power up, it is configured as a Display
Only module.
VOICE SYSTEM MODULES
AIC Audio Input Card The AIC (Audio Input Card) is a card that provides two external
isolated analog audio inputs to the voice system. External audio
sources can be any of the following: tape recorder, CD player, radio,
PBX interface (for convenience paging through the telephone sys-
tem), etc.
The AIC contains two dry contact inputs to activate the two audio
inputs separately.
Each input can be configured independently for different usages via
the Zeus programming tool. Each input can be controlled automati-
cally via system logic dependant on its individual configuration or
manually by using the voice control panel. The input levels can be
adjusted via the Zeus tool or manually with push buttons at the AIC
front panel. During the initial power-up condition, each input is shut off.
12345678
12345678
910111213141516
910111213141516
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
TB2
TB1
P2
S1 S2
P3
TB3
1
1
6
6
TB4
SIM-16
AUDIBLES
SILENCED
ON
SUPERVISORY
ALARM
LOCAL
ACK
TROUBLE
SECURITY
ZONE 1 ACT
ZONE 2 ACT
NORMAL
NORMAL
OVERLOAD
OVERLOAD
ZONE 1 TRBL
ZONE 2 TRBL
LOW
LOW
ZONE 1
ZONE 2
CARD FAIL
ASI FAIL
CAN FAIL
RESET
POWER
AIC
CAN
+
-
1
+
-
2
Komentáře k této Příručce