Siemens FIREFINDER-XLS Uživatelský manuál Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 6
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
s Industry, Inc.
Building Technologies Division
Fire Safety
8 Fernwood Road
Florham Park, NJ 07932
Tel: (973) 593-2600
FAX: (908) 547-6877
URL: www.usa.Siemens.com/Fire
(SII-FS)
Printed in U.S.A.
Fire Safety
2 Kenview Boulevard
Brampton, Ontario
L6T 5E4 / Canada
Tel: (905) 799-9937
FAX: (905) 799-9858
June 2013
Supersedes sheet dated 6/11
(Rev. 7)
Remote Telephone Stations (continued)
The remote telephone station must be used with
either the FB-300 or FB-301S remote telephone-station
back box. The FB-300 is used for flush-mount
configurations, and the FB301S is used for surface-mount
configurations. The remote station / back box assembly
also requires the FC-300S cover with key-lock door and
breakable glass.
FT-GLS
FT-GLS Replacement Glass
Additional replacement glass for the FC300S is
available as the Model FT-GLS.
ALCC
ALCC Audio Level Conversion Card
The Audio Level Conversion Card (Model ALCC) provides the
capability of conducting a global-emergency page across
multiple, remote FireFinder XLSV nodes with each audio riser
holding a maximum of 63 nodes.
The emergency page originates at a FireFinder XLSV or MXLV
global-paging station, where it is broadcast at 70VRMS over an
audio riser by Model ZAC-40 (FireFinder XLSV) or Model
ZAC-30 (MXLV) amplifier.
Temperature and Humidity Range
Products are
UL 864 9
th
Edition Listed for indoor dry
locations within a temperature range of 120+/-3°F
(49+/-2°C) to 32+/-3°F (0+/-2°C) and at a relative
humidity of 93+/-2% at a temperature of 90+/-3°F
(32+/-2°C).
XDMC
XDMC Digital Message Card
The Digital Message Card (Model XDMC) provides the
capability of programming and sounding custom voice
messages for Evacuation, Alert, Tornado Warning, System
Testing and other emergency and non-emergency building-
notification requirements.
Model XDMC, which serves as a XLSV optional module, plugs
into an available expansion slot in the Model CC-2 / CC-5 card
cage. Each XLSV system can support a maximum two (2)
Model XDMC modules. Each Model XDMC can be
programmed for up to 300 different custom messages.
Details for Ordering
Model
Number
Part
Number
Description
AIC 500-035300
Audio-
Input Card
ALCC 500-650127 Audio Level Conversion Card
DAC-NET 500-035100 Digital Audio Card
FB-300 500-680587 Remote Telephone Stations
FCM-6 500-033140
Fan Control Module Switches
(On / Off / Auto)
FJ-304 500-692670 Remote Telephone Jacks
FMT 500-034100 Fireman's Master Telephone
HCP 500-034860
Intelligent Control Point
LCM-8 500-033100
LED Annunciator Module
(8 LED Sets)
LPB 500-035200 Local Page Board
LVM 500-034090 Live Voice Module
PFT 500-699427 Portable Firefighters’ Telephones
PMI
500-033070
Operator
Interface/ System CPU
PMI-2
S54430-C1-A1
Person Machine
Interface 2
SCM-8 500-033040 Switch Module (8 Switches)
TZC-8B 500-034110 Firefighter's Telephone Zone Card
ZAC-40 500-035400 Zone Amplifier Card (40 Watt)
ZAM-180 500-035600 Zone Amplifier Module (180 Watt)
XDMC
S54430-B5-A1
Digital Message Card
Note: Equipment for FireFinder XLSV is listed and approved as part
of the FireFinder XLS system.
See data sheet: 6300 for ordering information