SINAMICS G120
Inverter chassis units 0.37 kW to 132 kW (0.5 hp to 200 hp)
SINAMICS G120 chassis units
3/7
Siemens D 11.1 · 2008
3
Design (continued)
General information on design
Frequency converters, consisting of Power Module (PM) and Control Unit
(CU) and two base components at positions 1 and 2
Max. two base components plus converter are possible.
The line filter has to be mounted directly underneath the fre-
quency inverter (position 1).
With lateral mounting, the line-side components have to be
mounted on the left side of the frequency inverter and the
load-side components on the right side.
Braking resistors have to be mounted directly on the control
cabinet wall due to heating issues.
Recommended installation combinations of converter and optional power and DC link components
Inverter chassis unit
SINAMICS G120 e. g.
Filter
Base components
e. g.
Reactor
Mounting
surface or
cabinet wall
Position
1
Position
2
G_D011_EN_00187
CU PM
Power Module Base component Lateral mounting
Frame size Position 1 Position 2 On the left side of the
converter
(for line-side power
components)
On the right side of the
converter
(for output-side power
components and DC link
components)
FSA and FSB
Line filter Line reactor Output reactor and/or
Braking resistor
Line filter or
Line reactor
Output reactor Braking resistor
Line filter or
Line reactor
Braking resistor
Line filter or
Line reactor or
Braking resistor
FSC
Line filter Line reactor Output reactor and/or
Braking resistor
Line filter or
Line reactor
Output reactor Braking resistor
FSD and FSE
Line reactor Line filter Output reactor and/or
Braking resistor
FSF
Line filter and/or
Line reactor
Output reactor and/or
Braking resistor
© Siemens AG 2008
Zobrazit stránku 6