Shrnutí obsahu

Strany 1

Created with "Chameleon CMYK PDF Creator" for Wolfgang Strozyk at Siemens AGThis catalog is out of date, see note on page 2

Strany 2 - TELEPERM M

Mode of operationSiemens PLT 130.19942/5Configuring of communicationConfiguring of communicationSince the communication via the CS 275 bus system is h

Strany 3

Siemens PLT 130.19942/6Created with "Chameleon CMYK PDF Creator" for Wolfgang Strozyk at Siemens AGThis catalog is out of date, see note on

Strany 4

DesignSiemens PLT 130.19943/1Contents PageGeneral notes 3/2Local range 3/2Remote range 3/3Bus components 3/3Technical data 3/5Bus configurations 3/6Cr

Strany 5

DesignSiemens PLT 130.19943/2General notes, local rangeThe CS 275 bus system is physically divided into-- a local rangeup to 20 m (local bus) and-- a

Strany 6

DesignSiemens PLT 130.19943/3Remote range, bus componentsThe following therefore applies:In the case of electrically isolated local bus interface modu

Strany 7

DesignSiemens PLT 130.19943/4Bus componentsConnector boardAFThe remote bus cable is connected to the bus converter via theconnector board AF.The board

Strany 8

DesignSiemens PLT 130.19943/5Bus components, technical dataOvervoltage protectionThe participants connected to the remote bus can be exten-sively prot

Strany 9

DesignSiemens PLT 130.19943/6Bus configurationsBus configuration,examplesApplication Other conditions Cable connectors20-m local bus Small plantsMax.

Strany 10 - Mode of operation

Modules andordering data4/1Contents PageInterface modules for 20-m local busN-AS 4/2N-BK 4/3N16-M 4/4N-V.24 4/5N-S5 4/7N-AT 4/8Bus converter UI 4/9Con

Strany 11 - Siemens PLT 130

Siemens PLT 130.19944/2Interface modules for 20-m local bus (N-AS), 8 bitDescription and ordering data1 LED (yellow), signals ”maintenance protocol st

Strany 12 - Contents Page

SummaryMode of operationDesignModules andorderi ng dataAppendixSY--TRANS 300 CS GatewayDocumentation forCS 275 bus systemSubject indexCS 275 Bus Syste

Strany 13

Siemens PLT 130.19944/3Interface module for 20-m local bus (N-BK)Description and ordering data1 LED W (yellow), signals ”maintenance protocol stored”2

Strany 14

Siemens PLT 130.19944/4Interface module for 20-m local bus (N16-M), 16 bitDescription and ordering data1 LED F (red), signals faults (line protocol fa

Strany 15

Siemens PLT 130.19944/5Interface module for 20-m local bus (N-V.24)Description1 LED F (red), signals faults (line protocol faulty, receiver memory ove

Strany 16

Siemens PLT 130.19944/6Interface module for 20-m local bus (N-V.24)Technical data and ordering dataThis circuit cancels theelectrical isolation of the

Strany 17 - Bus configuration

Siemens PLT 130.19944/7Interface module for 20-m local bus (N-S5)Description and ordering data1 LED F (red), signals faults (line protocol faulty,rece

Strany 18 - Modules and

Siemens PLT 130.19944/8Interface module for 20-m local bus (N-AT)Description and ordering dataFig. 4/8 Interface module for 20-m local bus (N-AT)Appli

Strany 19

Siemens PLT 130.19944/9Bus converter unit UIDescription and ordering data1 LED ET (green), flashes in rhythm with the messages receivedfrom the remote

Strany 20

Siemens PLT 130.19944/10Connector board AFDescription and ordering dataFig. 4/11 Connector board AF ”Remote bus” 6DS9 203--8DA, withmounting plateAppl

Strany 21

Siemens PLT 130.19944/11Remote bus connection unit FAE1 Connection distributor for 20-m local bus, 6DS9 207-8AA;for commissioning and servicing, can b

Strany 22

Siemens PLT 130.19944/12Remote bus connection subrack S5Description and ordering data1 Mains terminal s AC 230 V2 Power supply modules3 Bus converters

Strany 23 - Ordering data

SummarySiemens PLT 130.19941/2The TELEPERM M process control system consists of function-ally different components which are optimized for the various

Strany 24

Siemens PLT 130.19944/13Bus couplerDescriptionFig. 4/18 Bus coupler (BK--FF), subrack configurationApplicationBus couplers are used for data transfer

Strany 25

Siemens PLT 130.19944/14Bus couplerTechnical data and ordering dataAF Connector board ”Remote bus”UI Bus converterFig. 4/20 Bus coupler BK-FF, functio

Strany 26 - Bus converter unit UI

Siemens PLT 130.19944/15Fr ont plug for 20-m local busDescription and ordering dataFig. 4/21 Front plug 6DS9 200-8AA (ES 902 plug)ApplicationTo connec

Strany 27 - Connector board AF

Siemens PLT 130.19944/16Overvoltage protectionDescriptionFig. 4/23 Coarse overvoltage protection 6DS9 208-8AAApplicationThe coarse and fine overvoltag

Strany 28

Siemens PLT 130.19944/17Overvoltage protectionConfiguring notes and ordering dataAF Connector board ”Remote bus” GS Coarse overvoltage protection Cabl

Strany 29

Siemens PLT 130.19944/18Remote bus cablesStandard remote bus cable Remote bus cable for special applicationsFig. 4/26 Standard remote bus cableApplica

Strany 30 - Bus coupler

Siemens PLT 130.19944/19Connection of remote bus cablesIt may be necessary when using remote bus cables to connectsections together . The type of conn

Strany 31

Siemens PLT 130.19944/20Created with "Chameleon CMYK PDF Creator" for Wolfgang Strozyk at Siemens AGThis catalog is out of date, see note on

Strany 32

Appendix5/1Siemens PLT 130.1994Contents PageSY-TRANS 300 CS Gateway 5/2Documentation for CS 275 bus system 5/4Subject index 5/5Conditions of sale and

Strany 33 - Overvoltage protection

Siemens PLT 130.19945/2SY--TRANS 300 CS gatewayDescriptionBild 5/1 SY--TRANS 300 CS gatewayApplicationThe SY-TRANS 300 CS gateway enables bidirectiona

Strany 34

SummarySiemens PLT 130.19941/3The bus system can be designed in redundant form if extremelyhigh demands are placed on the availability. This does not

Strany 35 - Remote bus cables

Siemens PLT 130.19945/3SY-TRANS 300 CS gatewayTechnical data and Ordering dataTechnical dataEthernet interface IEEE 802.3 10Base2/10Base5(thin/thick-w

Strany 36

Siemens PLT 130.19945/4AppendixDocumentation for CS 275 bus systemOrdering dataOrder No.Manual ”CS 275 bus system”including the foll owing instruction

Strany 37

Siemens PLT 130.19945/5AppendixSubject indexPageAAddressing 2/3BBus components 3/3Bus configurations 3/6Bus converter unit UI 3/4, 4/9Bus coupler 3/4,

Strany 38 - Appendix

Siemens PLT 130.19941/4Created with "Chameleon CMYK PDF Creator" for Wolfgang Strozyk at Siemens AGThis catalog is out of date, see note on

Strany 39 - SY--TRANS 300 CS gateway

Mode of operationSiemens PLT 130.19942/1Contents PageTransfer control 2/2Data protection 2/2Data transfer 2/2Addressing 2/3Transmission modes 2/3Redun

Strany 40 - SY-TRANS 300 CS gateway

Mode of operationSiemens PLT 130.19942/2Transfer control, data protection and transferTransfer controlSequential data transmission systems require a t

Strany 41

Mode of operationSiemens PLT 130.19942/3Addressing, transmission modesThis method has the following important advantages:There is far less loading on

Strany 42

Mode of operationSiemens PLT 130.19942/4Redundant operation mode, transmission reliability, synchronizationRedundant operation modeThe CS 275 bus syst