Siemens CP 243-2 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Siemens CP 243-2. Siemens CP 243-2 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 150
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Preface Contents
Technical Description and
Installation Instructions
1
Interface to the User Program
in the S7-200 CPU
2
Access to the Data of the AS-i
Slaves
3
Signaling Errors and Diagno-
stics in the User Program
4
Command Interface
5
Eliminating Problems /
Error Displays
6
Appendix
AS-Interface Protocol Imple-
mentation Conformance State-
ments
A
References
B
Note on the CE Mark
C
Support and Training
D
Glossary, Index
07/2000
C79000-G8976-C142
Release 02
CP 243-2
AS-Interface Master
Manual
SIMATIC NET
Industrial Ethernet
PROFIBUS
AS-Interface
AS-Interface
Zobrazit stránku 0
1 2 3 4 5 6 ... 149 150

Shrnutí obsahu

Strany 1 - AS-Interface

Preface ContentsTechnical Description and Installation Instructions1Interface to the User Programin the S7-200 CPU2Access to the Data of the AS-iSlave

Strany 2 - Trademarks

Technical Description and Installation Instructions1-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.1 General Notes on Operation – Safety Warn

Strany 3 - Diskette with Sample Programs

Command Interface5-32SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.17 Get_Extended_Total_ConfigurationPurposeWith this command, the followin

Strany 4

Command Interface5-33SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022 8 LASslave16BLASslave17BLASslave18BLASslave19BLASslave20BLASslave21BLASslav

Strany 5 - Contents

Command Interface5-34SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025 6 ID_CODE slave 22 I/O configuration slave 225 7 Ext ID1 slave 22 Ext ID2 s

Strany 6

Command Interface5-35SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/028 8 ID_CODE slave 15B I/O configuration slave 15B8 9 Ext ID1 slave 15B Ext ID

Strany 7

Command Interface5-36SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/0211 10 reserved Parameter slave 1B11 11 Parameter slave 2B Parameter slave 3B1

Strany 8

Command Interface5-37SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.18 Store_Extended_Total_ConfigurationPurposeWith this call, the required

Strany 9 - Instructions

Command Interface5-38SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022 10 ID_CODE slave 0 I/O configuration slave 02 11 Ext ID1 Slave 0 Ext ID2 sl

Strany 10 - C79000-G8976-C142/02

Command Interface5-39SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025 12 ID_CODE slave 25 I/O configuration slave 255 13 Ext ID1 Slave 25 Ext ID2

Strany 11 - 1.2 Uses of the Module

Command Interface5-40SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/028 14 ID_CODE slave 18B I/O configuration slave 18B8 15 Ext ID1 Slave 18B Ext

Strany 12 - Components Supplied

Command Interface5-41SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/0212 0 Parameter slave 12B Parameter slave 13B12 1 Parameter slave 14B Paramete

Strany 13

Technical Description and Installation Instructions1-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.2 Uses of the Module DP Slave and AS-i Mas

Strany 14 - 1.4 Installing the Module

Command Interface5-42SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Structure of the Job Data in the Receive BufferBank Byte Meaning2 0 Echo of t

Strany 15 - Figure 1-2

Command Interface5-43SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.19 Write_Extended_Parameter_ListPurposeWith this command, the parameters

Strany 16 - 1.6 Terminal Block

Command Interface5-44SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Structure of the Job Data in the Receive BufferBank Byte Meaning1 1 Echo of t

Strany 17

Command Interface5-45SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.20 Read_Extended_Parameter_Echo_ListPurposeWhen the parameters are transf

Strany 18 - 1.7 Modes of the CP 243-2

Command Interface5-46SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023 9 Par echo slave 14B Parameters slave 15B3 10 Par echo slave 16B Par echo s

Strany 19 - SET Button

Command Interface5-47SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.21 Read_Version_IDPurposeWith this call, the version ID of the CP 243-2 f

Strany 20 - 1.8.1 Status Display

Command Interface5-48SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.22 Read_AS-i_Slave_IDPurposeWith this call, the ID code of an AS-i slave

Strany 21

Command Interface5-49SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.23 Read_AS-i_Slave_ID1PurposeWith this call, the ID1 code of an AS-i slav

Strany 22 - 1.8.2 Slave Display

Command Interface5-50SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.24 Write_AS-i_Slave_Extended_ID1PurposeWith this call, the extended ID1 c

Strany 23 - Example of a Slave Display

Command Interface5-51SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.25 Read_AS-i_Slave_ID2PurposeWith this call, the ID2 code of an AS-i slav

Strany 24 - Protected Mode

Technical Description and Installation Instructions1-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Components SuppliedThe CP 243-2 product incl

Strany 25 - Configuring

Command Interface5-52SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.26 Read_AS-i_Slave_I/OPurposeWith this call, the I/O configuration of an

Strany 26

Command Interface5-53SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.27 Get_LPFPurposeWith this call, the list of peripheral faults (LPF) sign

Strany 27 - S7-200 CPU

Command Interface5-54SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.28 Write_AS-i_Slave_Parameter_StringPurposeWith this call, a parameter st

Strany 28 - 2.1 Overview

Command Interface5-55SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.29 Read_AS-i_Slave_Parameter_StringPurposeWith this call, a parameter str

Strany 29 - Analog Module

Command Interface5-56SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.30 Read_AS-i_Slave_ID_StringPurposeWith this call, an identification stri

Strany 30 - Examples

Command Interface5-57SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.31 Read_AS-i_Slave_Diagnostic_StringPurposeWith this call, an diagnostic

Strany 31

Command Interface5-58SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.32 Read_Data_and_Delta_ListPurposeWith this call, the AS-i error bits, th

Strany 32

Command Interface5-59SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023 12 Data slave 20B Data slave 21B3 13 Data slave 22B Data slave 13B3 14 Data

Strany 33 - Figure 2-2

Command Interface5-60SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 34 - Range of Values

6-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Dealing with Problems / Error DisplaysThis chapter contains information about special operating

Strany 35 - Meaning for the User Program

Technical Description and Installation Instructions1-5SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.3 Technical Specifications of the ModuleTh

Strany 36 - Description of the Bits

Dealing with Problems / Error Displays6-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/026.1 Replacing a Defective AS-Interface Slave/Automatic Ad

Strany 37 - Structure of the Control Byte

Dealing with Problems / Error Displays6-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/026.2 Error Displays of the CP 243-2 / Remedying Errors<

Strany 38

Dealing with Problems / Error Displays6-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 6-1 Error Displays of the CP 243-2 / Remedying Erro

Strany 39

Dealing with Problems / Error Displays6-5SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 6-1 Error Displays of the CP 243-2 / Remedying Erro

Strany 40

Dealing with Problems / Error Displays6-6SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 41

A-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02AS-Interface Protocol Implementation Conformance Statement (PICS)PICS for the CP 243-2Table A-1

Strany 42 - Access in the User Program

AS-Interface Protocol ImplementationA-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table A-2 , continuedNo. Comment / Function implemented by

Strany 43

AS-Interface Protocol ImplementationA-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table A-2 , continuedNo. Comment / Function implemented by

Strany 44 - 2.5.1 Analog Input Area

AS-Interface Protocol ImplementationA-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02How the AS-Interface cycle time depends on the number of co

Strany 45 - Banks 16–30: Reserved area

B-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02References/1/AS-Interface:The Actuator-Sensor-Interface for AutomationWerner Kriesel, O.W. Made

Strany 46 - Banks 48–63: Reserved area

Technical Description and Installation Instructions1-6SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.4 Installing the ModuleSlots in the S7-200

Strany 47 - 2.5.2 Analog Output Area

ReferencesB-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02/5/Profibus & AS-InterfaceComponents on the Field BusCatalog ST PIThe catalog can

Strany 48

C-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Notes on the CE MarkProduct NameCP 243-2 Order no.: 6GK7243-2AX00-0XA0EU Directive EMC 89/336/

Strany 49

Notes on the CE MarkC-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 50 - Access to the Binary Values

D-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02SIMATIC NET – Support and TrainingSIMATIC Training CenterTo help you to become familiar with th

Strany 51 - Analog Output Area of the CP)

SIMATIC NET – Support and TrainingD-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02SIMATIC Premium Hotline(Calls charged, only with SIMATIC Card

Strany 52

Glossary-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02GlossaryAPFAS-i Power Fail. Flag or LED display that indicates that the power supply on

Strany 53

GlossaryGlossary-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02AS-i moduleFor the AS-Interface, a module concept has been defined that allows t

Strany 54 - output bytes16

GlossaryGlossary-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02NibbleA nibble is a unit of information consisting of four bits.Standard AS-i ma

Strany 55 - Data Access with STEP 7 Micro

GlossaryGlossary-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 56 - Access to the Analog Values

IndexIndex-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02IndexAAddressingAS-i slaves, 3-2example, 3-6examples, 2-4the CP 243-2 in the S7-200 CP

Strany 57

Technical Description and Installation Instructions1-7SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.5 Front Panel – Access to all FunctionsCon

Strany 58

IndexIndex-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02EError displays, 6-1Error register, 2-7, 2-13in the analog module, 2-15in the digital

Strany 59

Technical Description and Installation Instructions1-8SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.6 Terminal BlockConnectionsThe CP 243-2 ha

Strany 60

Technical Description and Installation Instructions1-9SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02NoteFunctional groundThe CP 243-2 has a conn

Strany 61

Technical Description and Installation Instructions1-10SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.7 Modes of the CP 243-2Standard Operation

Strany 62 - Special Situations

Technical Description and Installation Instructions1-11SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.8 Displays and Operator ControlsChanging

Strany 63

Safety GuidelinesThis manual contains notices which you should observe to ensure your own personal safety, as well as toprotect the product and connec

Strany 64

Technical Description and Installation Instructions1-12SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.8.1 Status Display Interpreting the Statu

Strany 65 - User Program

Technical Description and Installation Instructions1-13SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 1-2 , continuedLED (color) MeaningSta

Strany 66 - 4.1 Signaling

Technical Description and Installation Instructions1-14SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.8.2 Slave DisplayInterpreting the Slave D

Strany 67 - Table 4-1

Technical Description and Installation Instructions1-15SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Example of a Slave DisplayFrom the display

Strany 68

Technical Description and Installation Instructions1-16SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/021.9 Configuring the AS-Interface with the S

Strany 69

Technical Description and Installation Instructions1-17SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02NoteChanging from the configuration mode to

Strany 70

Technical Description and Installation Instructions1-18SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 71 - Command Sequence

2-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Interface to the User Program in theS7-200 CPUThis chapter explains how the CP 243-2 is address

Strany 72

Interface to the User Program in the S7-200 CPU2-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.1 OverviewCP 243-2 as Expansion Module in the

Strany 73

Interface to the User Program in the S7-200 CPU2-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Analog ModuleThe analog module occupies 16 input

Strany 74

iSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02PrefacePurpose of the ManualThis manual supports you when using the CP 243-2 module. It explains

Strany 75 - Overview

Interface to the User Program in the S7-200 CPU2-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.2 Addressing the CP 243-2 in the S7-200 CPUAdd

Strany 76

Interface to the User Program in the S7-200 CPU2-5SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02 Example of a CPU 224 and a CP 243-2 Inserted D

Strany 77

Interface to the User Program in the S7-200 CPU2-6SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02 Example of a CPU 224, an 8DI Module, a 3AI/1AO

Strany 78

Interface to the User Program in the S7-200 CPU2-7SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.3 Meaning of the Data in the Digital ModuleOve

Strany 79 - Command Status

Interface to the User Program in the S7-200 CPU2-8SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.3.1 Identification Register in the Digital Mod

Strany 80

Interface to the User Program in the S7-200 CPU2-9SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.3.2 Error Register in the Digital ModuleMeanin

Strany 81 - 5.2.1 Set_Permanent_Parameter

Interface to the User Program in the S7-200 CPU2-10SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.3.3 Status Byte (Input Register 8DI)Meaning f

Strany 82 - 5.2.2 Get_Permanent_Parameter

Interface to the User Program in the S7-200 CPU2-11SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.3.4 Control Byte (Output Register 8DO)Meaning

Strany 83 - 5.2.3 Write_Parameter

Interface to the User Program in the S7-200 CPU2-12SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.4 Meaning of the Data in the Analog ModuleOve

Strany 84 - 5.2.4 Read_Parameter

Interface to the User Program in the S7-200 CPU2-13SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.4.1 Identification Register in the Analog Mod

Strany 85 - 5.2.5 Store_Actual_Parameters

PrefaceiiSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 86

Interface to the User Program in the S7-200 CPU2-14SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.4.2 Error Register in the Analog ModuleMeanin

Strany 87

Interface to the User Program in the S7-200 CPU2-15SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Example of Access to the Error RegisterAssuming

Strany 88 - Purpose of the Command

Interface to the User Program in the S7-200 CPU2-16SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.5 Access to the Analog Input and Output Words

Strany 89

Interface to the User Program in the S7-200 CPU2-17SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02BS5 Bank No.BS0BS1BS2BS3BS40 1 1 0 1 0 Bank 26

Strany 90 - 5.2.10 Set_Extended_LPS

Interface to the User Program in the S7-200 CPU2-18SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.5.1 Analog Input AreaAssignment of the Input

Strany 91 - 5.2.11 Set_Offline_Mode

Interface to the User Program in the S7-200 CPU2-19SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank 1: Diagnostics on the AS-Interface The del

Strany 92 - 5.2.12 Select_Autoprogramming

Interface to the User Program in the S7-200 CPU2-20SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Banks 32–47: Analog input data of the AS-i slav

Strany 93 - 5.2.13 Set_Operation_Mode

Interface to the User Program in the S7-200 CPU2-21SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022.5.2 Analog Output AreaAssignment of the Outpu

Strany 94

Interface to the User Program in the S7-200 CPU2-22SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Banks 2–15: Command data on the AS-InterfaceVia

Strany 95 - 5.2.15 Get_AS-i_Slave_Status

3-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Access to the Data of the AS-i SlavesThis chapter explains the AS-i master interface of the CP

Strany 96

iiiSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Contents1 Technical Description and Installation Instructions 1-1. . . . . . . . . . . . . . .

Strany 97

Access to the Data of the AS-i Slaves3-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023.1 Access to the Binary Data of the AS-i Slaves3.1.1 Addr

Strany 98

Access to the Data of the AS-i Slaves3-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Assignment of the AS-i Input Data of the Standard or A Sla

Strany 99 - Meaning of the Flags

Access to the Data of the AS-i Slaves3-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Assignment of the AS-i Input Data of the B Slaves (Bank 31

Strany 100 - Command Interface

Access to the Data of the AS-i Slaves3-5SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Data Exchange in the STOP Mode of the S7-22x CPUIn the STO

Strany 101

Access to the Data of the AS-i Slaves3-6SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02ExampleFigure 3-1 shows an example of the CP 243-2 address

Strany 102

Access to the Data of the AS-i Slaves3-7SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023.1.2 Access to the AS-i User DataData Access with STEP 7

Strany 103

Access to the Data of the AS-i Slaves3-8SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023.2 Access to the Analog Data of the AS-i Slaves(Slaves co

Strany 104

Access to the Data of the AS-i Slaves3-9SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank MeaningByte no.33 0 Slave 3, channel 1, high byte33 1

Strany 105

Access to the Data of the AS-i Slaves3-10SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank MeaningByte no.36 1 Slave 9, channel 1, low byte36 2

Strany 106

Access to the Data of the AS-i Slaves3-11SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank MeaningByte no.39 2 Slave 15, channel 2, high byte39

Strany 107

ContentsivSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/024 Signaling Errors and Diagnostics in the User Program 4-1. . . . . . . . . . . . . . .

Strany 108

Access to the Data of the AS-i Slaves3-12SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank MeaningByte no.42 3 Slave 21, channel 2, low byte42

Strany 109

Access to the Data of the AS-i Slaves3-13SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Bank MeaningByte no.45 4 Slave 27, channel 3, high byte45

Strany 110

Access to the Data of the AS-i Slaves3-14SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Representation of the Analog ValuesThe analog values must

Strany 111

Access to the Data of the AS-i Slaves3-15SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/023.2.2 Access to the AS-i Analog DataData Access with STEP

Strany 112

Access to the Data of the AS-i Slaves3-16SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 113

4-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Signaling Errors and Diagnostics in theUser ProgramThis chapter explains which errors of the CP

Strany 114

Signaling Errors and Diagnostics in the User Program4-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/024.1 SignalingError SignalingIf the CP 243-2

Strany 115 - 5.2.21 Read_Version_ID

Signaling Errors and Diagnostics in the User Program4-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/024.2 Example: Reading the Delta ListSTL Exam

Strany 116 - 5.2.22 Read_AS-i_Slave_ID

Signaling Errors and Diagnostics in the User Program4-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 117 - 5.2.23 Read_AS-i_Slave_ID1

5-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Command InterfaceVia the command interface, you can control the response of the AS-i mastercomp

Strany 118

ContentsvSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02A AS-Interface Protocol Implementation Conformance Statement (PICS) A-1. . . . . B Refere

Strany 119 - 5.2.25 Read_AS-i_Slave_ID2

Command Interface5-2SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.1 Command interface of the CP 243-2Command Buffer and Response BufferCommand

Strany 120 - 5.2.26 Read_AS-i_Slave_I/O

Command Interface5-3SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Command SequenceThe diagram below shows the following: How to execute command

Strany 121 - 5.2.27 Get_LPF

Command Interface5-4SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02A command started by the CP 243-2 is executed completely regardless of thestat

Strany 122

Command Interface5-5SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 5-2 , continuedSI Q1.0, 1 //Select bank 5BMW VW748, AQW0, 8 //V m

Strany 123

Command Interface5-6SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 5-2 , continuedSI Q1.0, 1 //Select bank 9BMW AIW0, VW512, 8 //Ban

Strany 124

Command Interface5-7SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2 Description of the AS-i CommandsOverviewThe following sections describe th

Strany 125

Command Interface5-8SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Table 5-3 , continuedName CodingReturnParameterGet_AS-i_Slave_Status –>

Strany 126

Command Interface5-9SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02General Structure of the Command BufferDepending on the command, the command b

Strany 127

Command Interface5-10SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02General Structure of the Response BufferDepending on the command, the respons

Strany 128

Command Interface5-11SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Command StatusWhether or not the job was executed correctly or errors occurre

Strany 129

ContentsviSIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02

Strany 130 - Programming

Command Interface5-12SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02General Structure of the AS-i Slave AddressIf an AS-i slave is addressed in a

Strany 131

Command Interface5-13SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.1 Set_Permanent_ParameterPurposeWith this call, a parameter value for the

Strany 132

Command Interface5-14SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.2 Get_Permanent_ParameterPurposeWith this call, a slave-specific paramete

Strany 133

Command Interface5-15SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.3 Write_ParameterPurpose of the CommandThe AS-i parameter value transferr

Strany 134

Command Interface5-16SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.4 Read_ParameterPurposeThis call returns the current parameter value (act

Strany 135 - Conformance Statement (PICS)

Command Interface5-17SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.5 Store_Actual_ParametersPurposeThis call overwrites the permanently stor

Strany 136

Command Interface5-18SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.6 Set_Extended_Permanent_ConfigurationPurposeThis call sets the following

Strany 137

Command Interface5-19SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.7 Get_Extended_Permanent_ConfigurationPurposeThis call reads the followin

Strany 138

Command Interface5-20SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.8 Store_Actual_ConfigurationPurpose of the CommandWith this call, the (ac

Strany 139 - References

Command Interface5-21SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.9 Get_Extended_Actual_ConfigurationPurpose of the CommandWith this call,

Strany 140 - Order numbers

1-1SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Technical Description and InstallationInstructionsThis chapter outlines the basic functions of

Strany 141 - Notes on the CE Mark

Command Interface5-22SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.10 Set_Extended_LPSPurposeWith this call, the list of configured AS-i sla

Strany 142

Command Interface5-23SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.11 Set_Offline_ModePurposeThis call switches between the online and offli

Strany 143 - SIMATIC Training Center

Command Interface5-24SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.12 Select_AutoprogrammingPurposeThis call can enable or disable the “auto

Strany 144 - Further Support

Command Interface5-25SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.13 Set_Operation_ModePurpose of the CommandWith this call, you can select

Strany 145 - Glossary

Command Interface5-26SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.14 Change_AS-i_Slave_AddressPurpose of the CommandWith this call, the add

Strany 146

Command Interface5-27SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.15 Get_AS-i_Slave_StatusPurposeWith this call, the status register of the

Strany 147

Command Interface5-28SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Structure of the Job Data in the Receive BufferBank Byte MeaningBit 7 Bit 4 B

Strany 148

Command Interface5-29SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/025.2.16 Get_LPS, Get_LAS, Get_LDS, Get_FlagsPurposeWith this call, the followi

Strany 149

Command Interface5-30SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/022 11 LDSslave 8LDSslave 9LDSslave 10LDSslave 11LDSslave 12LDSslave 13LDSslave

Strany 150

Command Interface5-31SIMATIC NET CP 243-2 AS-i MasterC79000-G8976-C142/02Meaning of the FlagsOFFLINE_READY The flag is set when the offline phase is a

Komentáře k této Příručce

Žádné komentáře