Siemens EF 847 Series Uživatelský manuál Strana 26

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 31
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 25
Page 26 of 31
Siemens Industry, Inc.
Multi-state Output Object Type
Property_Identifier
Supported
Writable
Object_Identifier
Required \
Optional
Yes R
Object_Name Yes R
Object_Type Yes R
Present_Value Yes Yes W
Description Yes Yes O
Device_Type Yes O
Status_Flags Yes R
Event_State Yes R
Reliability Yes O
Out_Of_Service Yes Yes R
Number_Of_States Yes R
State_Text Yes O
Priority_Array Yes R
Relinquish_default Yes R
Time_Delay Yes - Alarm O
Notification Class Yes - Alarm Yes O
Feedback_Value Yes - Alarm O
Event_Enable Yes - Alarm Yes O
Acked_Transitions Yes - Alarm O
Notify_Type Yes - Alarm O
Event_Time_Stamps Yes - Alarm O
Multi-state Value Object Type
Property_Identifier
Supported
Writable
Required \
Zobrazit stránku 25