Appendix A: Supported PLCs
Siemens Energy & Automation, Inc. 59
Note: The V-Memory word numbers in the above
table are shown in octal. These numbers
must be converted to decimal before they
are entered into the DTU3005 Configuration
Software. For example, if the DTU3005 is to
access register V02000, the value 2000 in
octal corresponds to the value 1024 in deci-
mal. The value 1024 is then entered into the
DTU3005 Editor Program.
Device data should be written to the data registers
starting at V02000 octal, or 1024 decimal for the
DTU3005 Editor Program.
A.6 Koyo/PLC Direct/TI 405 Series
PLCs
Registers Accessed
The DTU3005 can access all register types in the 405
Series PLC through the use of the V-Memory assign-
ments shown in the following table:
Note: The V-Memory word numbers in the above
table are shown in octal. These numbers
must be converted to decimal before they
are entered into the DTU3005 Configuration
Software. For example, if the DTU3005 is to
access register V02000, the value 2000 in
octal corresponds to the value 1024 in deci-
mal. The value 1024 is then entered into the
DTU3005 Editor Program.
Device data should be written to the data registers
starting at V01400 octal, or 768 decimal for the
DTU3005 Editor software.
A.7 Koyo/PLC Direct/TI 305 Series
PLCs
Registers Accessed
The DTU3005 will only access registers in the Data
Area of PLC memory (R400–R577 and R700–R777)
which are 8-bit registers. Because the DTU3005 will
only read and write 16-bit values, it will use two con-
secutive 8-bit registers in the 305 Series PLCs to form
a 16-bit value. The first of these consecutive registers
must be located on an even boundary (i.e. R400, R402,
etc.). The low order byte of the 16-bit value is located
in the lowest numbered register and the high order
byte is located in the highest numbered register.
When entering register numbers into the DTU3005
Configuration Software, they must be converted from
octal to decimal. For example, if the DTU3005 is to
access register R400 (and R401), the value 400 in octal
is converted to the value 256 in decimal. This value of
256 is then entered into the DTU3005 Editor Program.
A.8 Mitsubishi FX Series PLCs
Registers Accessed
The DTU3005 will only access registers in the Data
Register Area of PLC memory (D0 to D9999). When
entering register numbers, only the offset into this
area (0-9999) should be entered. For example, to
access register number D1, the value 1 should be
entered. To access register number D9999, the value
9999 should be entered.
RTS Control
The Mitsubishi FX-32 and equivalent PLCs require RTS
to be active when sending to the PLC and inactive
when receiving from the PLC. The DTU3005 can be
V01000 – V01177 Counter CT0 – CT177 Current Values
V02000 – V03777 Data Words V2000 – V3777
V04000 – V04377 Non-Volatile Data Words
V4000 – V4377
V40400 – V40423 Input Points X0 – X477
(16 per V-Memory word)
V40500 – V40523 Output Points Y0 – Y477
(16 per V-Memory word)
V40600 – V40617 Control Relays C0 – C377
(16 per V-Memory word)
V41000 – V41037 Stages S0 – S777
(16 per V-Memory word)
V41100 – V41107 Timer T0 – T177 Status Bits
(16 per V-Memory word)
V41140 – V41147 Counter CT0 – CT177 Status Bits
(16 per V-Memory word)
Table A.3 Koyo/PLC Direct/TI 405 Registers
V-Memory Address PLC Registers Accessed
V00000 – V00377 Timer T0 – T377 Current Values
V01000 – V01177 Counter CT0 – CT177 Current Values
V01400 – V07377 Data Words V1400 – V7377
V10000 – V17777 Data Words V10000 – V17777
V40000 – V40077 Remote I/O GX0 – GX1777
(16 per V-Memory word)
V40400 – V40423 Input Points X0 – X477
(16 per V-Memory word)
V40500 – V40523 Output Points Y0 – Y477
(16 per V-Memory word)
V40600 – V40677 Control Relays C0 – C1777
(16 per V-Memory word)
Table A.2 Koyo/PLC Direct 205 Registers (Continued)
V-Memory Address PLC Registers Accessed
V41000 – V41077 Stages S0 – S1777
(16 per V-Memory word)
V41100 – V41117 Timer T0 – T377 Status Bits
(16 per V-Memory word)
V41140 – V41147 Counter CT0 – CT177 Status Bits
(16 per V-Memory word)
Table A.3 Koyo/PLC Direct/TI 405 Registers