Contents
SIMATIC NET PROFIBUS Optical Link Module OLM V4.0
Operating Instructions, 01/2013, C79000-G8976-C270-03
v
7 References .............................................................................................................................................. 51
7.1 References...................................................................................................................................51
8 Drawings.................................................................................................................................................. 53
Tables
Table 2-1
Number of electrical and optical ports per module, .......................................................................4
Table 4-1 Overview of the product characteristics.......................................................................................20
Table 4-2 DIL-switches in compatibility mode..............................................................................................24
Table 5-1 Meaning of the LED displays and indication by the signaling contact.........................................42
Table 5-2 Constants for calculating the slot time for DP-standard (redundant optical ring) ........................46
Table 5-3 Constants for calculating the slot time for DP/FMS (”universal“) and DP with S5 95U (redundant
optical ring)...................................................................................................................................46
Figures
Figure 2-1
PROFIBUS OLM with position of all interfaces, displays and adjustment options ........................3
Figure 3-1 Network structure in a linear (bus) optical topology.......................................................................8
Figure 3-2 Network structure with an optical star topology ...........................................................................10
Figure 3-3 Network structure with a redundant optical ring topology............................................................11
Figure 4-1 View of the OLM module from the top .........................................................................................22
Figure 4-2 Minimum cable length for use of plastic fiber S 980/1000 without fixed attenuator.....................27
Figure 5-1 Measures to suppress..................................................................................................................29
Figure 5-2 Securing shielded cables with cable clamps and cable retainers...............................................31
Figure 5-3 View of the module from below....................................................................................................33
Figure 5-4 Installation of a module on a standard DIN rail............................................................................34
Figure 5-5 Installation of a module with a mounting plate.............................................................................35
Figure 5-6 Drilling measures for the mounting plate, all dimensions are millimeter......................................36
Figure 5-7 Electrical port, connector assignment D-sub jack.......................................................................36
Figure 5-8 Operating power supply, pin assignment 5-pin terminal block ..................................................38
Figure 5-9 Signaling contact relay with floating contacts; ............................................................................38
Figure 5-10 Signaling contact, pin assignment 5 pin terminal block .............................................................38
Figure 5-11 Position of the level recording connections ................................................................................39
Figure 5-12 Relationship between measured output voltage and signal quality.............................................39
Figure 5-13 LED displays on the front panel...................................................................................................40
Komentáře k této Příručce