Mounting system equipment
Battery installation
34
Siemens AB
A6V10276959
Security Products
18.11.2011
+
CN23
T1 C T2
NO
NC
COM
1. Connect NO on the tamper switch to T1 on the controller.
2. Connect COM on the tamper switch to C on the controller. Ensure the T2
jumper is not removed.
3. When the tamper switch is wired, the controller can be commissioned in the
normal manner.
6.3 Battery installation
For EN50131 compliance the battery needs to be retained within the housing to
stop movement. This is achieved by bending out the flaps in the rear of the Hinged
Enclosure so that the battery is retained.
If a 7 Ah battery is used then the battery is biased to the left of the cabinet and
bottom flap is bent to meet the battery.
If a 17 Ah battery is used then the battery is biased to the right of the cabinet and
middle flap is bent to meet the battery.