Siemens SIMATIC IPC427C Provozní pokyny Strana 128

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 182
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 127
Detailed descriptions
16.2 BIOS Setup
SIMATIC IPC427C
128 Operating Instructions, 10/2010, A5E02414743-03
"Boot Options" submenu
Figure 16-5 "Boot Options" submenu
Quick Boot Mode Some hardware tests are skipped to speed up the boot sequence.
The boot sequence is stopped if an error is detected during booting; you
must press F1 to acknowledge.
Never halt on
errors
Booting continues if errors occur
Halt on all errors Booting is stopped if an error is detected
All without
keyboard
Booting is stopped if any error except a keyboard error
occurs
POST errors
All without
kb/smart
Stop at any error, but not with a keyboard or S.M.A.R.T
storage media error.
Diagnostic screen Shows the diagnostics messages on the monitor during booting.
Zobrazit stránku 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 181 182

Komentáře k této Příručce

Žádné komentáře