05.07 DNC Plant/DNC Cell (FBDN1)
10 Configuration
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/10-197
10.5.3 Configuration dialog for the SINUMERIK* connection type
Configuration dialog for the SINUMERIK* connection type
The machine configuration file is configured in the configuration dialog.
General tab page (SINUMERIK* machine configuration) [GLOBAL]
The General tab page is the [GLOBAL] section of the machine configuration file for
SINUMERIK* machine connections.
Fig. 10-14: Config dialog SINUMERIK* / General tab page
Machine IP address
Here, you enter the IP address or the name of the machine (controller).
Extract from the machine configuration file:
MachineIpAddress=PCU50
DMS path
This input field contains the path to the data management system on the
controller. To be able to access the data management system on the controller
from the DNC computer, a share must be set up on the controller.
Extract from the machine configuration file:
DHPath=f$\dh