DNC Plant/DNC Cell (FBDN1) 05.07
12 Auto archiving
© Siemens AG 2010 All Rights Reserved
FBDN1/12-264 Motion Control Information System DNC (FBDN) - 04/10 Edition
12.2 Configuring the auto archive function
12.2.1 General
To configure SINUMERIK* machines for automatic comparisons and archive runs,
you have to set the Auto Archive checkbox for the machine in DNC Admin. The
upload directory is always the machine directory.
Comparison basis for the auto archive run
NC data in the machine directory in the DNC system whose auto archive
identifier is set to 1 or 2 is compared with the NC data in the machine directory on
the relevant SINUMERIK*. If a version with an auto archive identifier is not found,
released NC data at the search level in the DNC system is compared with the NC
data in the machine directory on the relevant SINUMERIK*.
The comparison takes place on the basis of the change date and the length of the
files to be compared.
For each machine, you have to configure which DM directories for the machine and
which file types in these DM directories are to be compared/archived.
Auto archive time
To define the times at which the auto archive/comparison run takes place, enter
DNC Auto Archive in the Windows task scheduler.
These configurations are explained in more detail in the following sections.