Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–49
3.11.3 Replacing and installing distance or WT motor when faulty
Insert the new distance/ WT motor (2) into the frame plate (1).
When doing this insert the motor pinion (5) and collar (4) ø 11 mm (or collar
(4.1) ø 8 mm)
correctly into the frame plate (1).
Fix the distance/ WT motor (2) onto the frame plate (1) with the screws (3) 2.5
x 6 (or (3.1) 2.5 x 5).
3.11.4 Preparing frame plate (version till 09.87) for installing
distance/ WT motor (version from 10.87)
Fig. 3-35 Frame with three flange centring bars
Procedure
Shear off the three centring bars (8) with flat nosed pliers by rotating them.
On the front of the frame plate (1) remove parts from the motor pinion (5) until
the plastic parts (3) are accessible.
Cut through the lugs at position (A) with a knife.
Remove plastic parts (9).
Complete the frame plate (1) again at the motor pinion (5).
Remark
Repair:
Measurements on coil 2 or coil 2 are outside the specified tolerance.
1 Frame plate up to 09.87 8 Centring bars
5 Motor pinion 9 Plastic parts
8
A
5
A
9
Back until 09.87
Front until 09.87
1
9
Remark
When installing the distance/WT motor (from 10.87), without flange, modify
the frame plate (up to 9.87) with three centring bars (8).
There is no need to centre the flange (6) and adjust the tooth play to the pi-
nion (5).