4 Checking and adjusting
4–24 Section 4 © Siemens VDO Trading GmbH TU00-1318-0200302
4.10 Function check
The instructions in the TPH
1
,
Section 3 "Testing instructions"
Section 5 "Legal requirements"
must be observed. We would like to refer particularly to the following sections or chap-
ters:
If necessary incorrect functions must be corrected.
1 TU00. 1308. 01 000 01
Sec-
tion Chapter Topic Section
3 6 Checking the clockwork mechanism
Inserting the tachograph chart at the right time
Checking indicator operation.
6.1.1
6.1.3
6.1.4
3 7 Setting time group symbol
Warning control unit
Distance counter
7.1
7.3
7.4
3 8 Tachograph charts for test chart
Test chart/ testing procedure
Permissible inherent errors
8.1
8.2
8.3
8.4
8.5
3 5 Auto-diagnosis 5.6
2 7 Testing additional and special equipment 7