Siemens SIMATIC FS600 Provozní pokyny Strana 27

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 51
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 26
Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 27/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
Testing the LEDs at the laser scanner SIMATIC FS600
The laser scanner SIMATIC FS600 indicates its current status via five
LEDs:
LED Color Function / Meaning Pictogram
1
Green
Sensor function is active, active
detection zone is free
2
Yellow
Warning zone occupied
3
Red
OSSD outputs switched off
4
Green
OSSD outputs switched on
5
Yellow
Permanent light:
Restarting lockout
Slowly blinking (1):
Warning message (ca. 0.25 Hz)
Blinking fast (((1))):
Failure message (ca. 4 Hz)
Zobrazit stránku 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 50 51

Komentáře k této Příručce

Žádné komentáře