XMU+ Installation and Maintenance Guide rev.07 69
About XMU+ Operating Modes
Level Start/Pulse
Return - Single Play
(LS/PR-SP)
The message plays in
response to a start signal.
The CP contacts toggle
position for approximately
250 msec. at the start and
end of the message. The
message stops playing if
the start signal is removed.
Level Start/Pulse
Return - Multiple
Play (LS/PR-MP)
The message plays in
response to a start signal.
The CP contacts toggle
position for approximately
250 msec. at the start and
end of the message. The
message stops playing if
the start signal is removed.
The message plays
repeatedly until the start
signal is removed.
Level Start/Level
Return - Single Play
(LS/LR-SP)
The message plays in
response to a start signal.
The CP contacts toggle
position while the message
is playing. The message
stops playing if the start
signal is removed.