Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
122 Configuration Manual, 11/2014, C79000-G8976-C323-03
5.5
"System" menu
5.5.1
System Configuration
System configuration
The WBM page contains the configuration overview of the access options of the device.
Specify the services that access the device. With some services, there are further
configuration pages on which more detailed settings can be made.
Description
The page contains the following boxes:
"Telnet Server" check box
Enable or disable the "Telnet Server" service for unencrypted access to the CLI.
"SSH Server" check box
Enable or disable the "SSH Server" service for encrypted access to the CLI.
"HTTPS Server only" check box
Enable or disable access using HTTPS.