Siemens IEEE802.11 Provozní pokyny Strana 55

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 292
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 54
Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
55
Description
The page contains the following boxes:
"Telnet Server" check box
Enable or disable the "Telnet Server" service for unencrypted access to the CLI.
"SSH Server" check box
Enable or disable the "SSH Server" service for encrypted access to the CLI.
"HTTPS Server only" check box
Enable or disable access using HTTPS.
"DCP Server"
drop-down list
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read-Only
With DCP, device parameters can be read but cannot be modified.
"SNMP" drop-down list:
Select the protocol from the drop-down list. The following settings are possible:
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
SNMPv3
Access to device parameters is possible with SNMP version 3. You can configure
other settings in "System > SNMP > General".
"SNMPv1/v2 Read-Only"
check box
Enable or disable write access to SNMP variables with SNMPv1/v2c.
"
SINEMA Configuration Interface
" check box
If the SINEMA configuration interface is enabled, you can download configurations to the
device via the TIA Portal.
Zobrazit stránku 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 291 292

Komentáře k této Příručce

Žádné komentáře