27.4 Read or write to/from the memory stick (EEPROM)
Write To EEPROM
P200E 7E
This location is used to copy the panel program configuration to an external
Memory stick (IMM6-10) which can be plugged into the programming port on the
control panel. The write protect switch on the Memory stick must be ON for the
data to be transferred.
Read From EEPROM
P200E 8E
This location is used to return the panel program configuration from an external
Memory stick which can be plugged into the programming port on the control
panel.
When the system is plugged/ unplugged to the Memory stick it could happen that the system does a
restart automatically. We recommend to plug and unplug always under powerless condition (battery
and main disconnected from the panel to avoid damage).
27.5 Reset back to defaults
Clear User/Phone
P200E 9E
This location is used to return the panels User and Installer Codes plus the
Telephone Numbers & Account Codes to the default settings.
Clear All
P200E 10E
This location is used to return all other parameters back to the default settings.