Contact less card reader IAR6-30 for keypad bus connection
31
Building Technologies
Fire Safety & Security Products
5.3 Zone input for door monitoring
There is an optional input to monitor an exterior gate to show if it is currently
opened or closed. This input is not EOL monitored and should only be used for
non-critical monitoring functions. A zone can be programmed to use this input for
its trigger (see chapter
20.2: Zone type options- basic information; Zone A Options,
option 4; P122E) so that the state of the input can be displayed on a keypad. This
allows saving cabling, because the zone is connected directly to the card reader /
bus and does not request separate zone cabling
The inputs are linked to the selected keypad address programmed into the reader.
For example if the reader being used was programmed as keypad # 1, then the
input can be assigned to zone 1 or 9 (see chapter
20.2: Zone type options- basic
information; Zone A Options, option 4; P122E), if the keypad address was # 2, the
input can then be assigned to zone 2 or 15, etc.
5.4 Output for electrical door lock control
There is also an output available on this reader that follows the same addressing
functionality as described in the zone input function. It can be used to activate an
electric lock as shown in the connection drawing. This helps to save cabling.
The reader output can only control the electrical lock! The Sintony 60 is not able to supply power for
an external lock. An additional external power supply is recommended depending on the type of door
lock which is used.
5.5 Indication of status/address through LEDs
If requested the LED on the reader can be linked to an output so that special
functions may be displayed at the reader if desired (e.g. chapter
18.13: Learn a
card reader to the system, addressing an LED; Proximity LED Follows Output;
P98E).
5.6 Proximity readers connections
Bus connections- max. length*
Up to 25 meter, 22AWG,
wire diameter 0.6mm
7 Keypads IKP6-03 or
Reader IAR6-30
8 Keypads IKP6-03 or
Reader IAR6-30
Up to 100 meter, 20AWG,
wire diameter 0.8mm
4 Keypads IKP6-03 or
Reader IAR6-30
4 Keypads IKP6-03 or
Reader IAR6-30