Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 17
5.1.1 Using the SICK function module for PROFINET IO
If the optional SICK function module is used, the addresses of the I/O range incl. the correct length must be
assigned to the module. The block then takes over the handling of the Handshake mode and can thus also
receive data longer than the input range.
Download at
http://www.sick.com/software, Category "Function Module".
If the Function Module is used, use of Handshake Mode is obligatory.
The following variants are available:
a) CLV6xx/Lector6xx for S7 300/400 with integrated PROFINET / PROFIBUS for Step 7 V5.5 ("Classic")
b) CLV6xx/Lector6xx for S7 300/400 with integrated PROFINET / PROFIBUS for TIA V12 SP1 or higher.
(Migrated from Step 7 V5.5)
c) CLV6xx/Lector6xx for S7 1200/1500 with integrated PROFINET / PROFIBUS for TIA V12 SP1
or higher.
If desired, optional actions such as "Triggering via command", or "Alter Matchcode during operation" can
also be used.
More details are available in the documentation of the function block.
Here is an example of the function module for CLV6xx/Lector on a S7 300 with integrated PROFINET
based on Step 7 V5.5: