Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 37
Checking triggering and data output in No Handshake mode:
Triggering and monitoring of the data output can be performed easily using a variable table. In the
No Handshake mode, no program or function module is necessary.
Addressing selected in the example:
Trigger bit:
Q1.0 Bit 0 of Adr + 1 of "Ctrl Bits Out"
Counter for data:
from IB 256: Adr of "32 Byte Input"
User data:
from IB 261: Adr + 5 of "32 Byte Input"
Variable table:
The scanner can be controlled by setting the A1.0 bits marked in red:
1 Trigger on, 0 Trigger off
In the first byte EB256, Bit 2 is inverted every second (heartbeat bit).
The user data is visible in the area outlined in blue.
The "Receive Count" counter increments with each block of data received. On overflow, the 0 is
skipped: 1 to 255, 1 to 255.
In the example, eight data bytes were received, with the content "12345678".
For more details on data reception, see Chapter 5.2.