Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 35
GSDML configuration:
Note that GSDML configuration is optional and is sent to the CLV61x Dual Port every time PROFINET starts.
This overwrites the existing parameters in the CLV61x Dual Port.
Example:
GSDML configuration must always begin with "01_Start_Remote Config":
For this, only Code 128 was activated and triggering via fieldbus bit selected.
Secondly, reading configuration by the "11 Reading Config" module was selected:
For example, the scanning frequency can be adjusted here.
As this is a simple application, the Handshake mode is switched off.
Note:
No Handshake must be carried out on the PLC and simple operation with a short data string can
take place.
If the SICK function module is to be used, the Handshake must be switched on.
Additional configuration modules can be selected according to the application.
The process must always be completed with the "99_End_Remote Config" module.
The HW Config must finally be saved and transferred to the PLC.