Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 34
7 Appendix
7.1 Quickstart CLV61x Dual Port – simple example with GSDML configuration
Quickstart describes the commissioning of the CLV61x Dual Port with GSDML configuration by the
PROFINET Controller (PLC) centrally. A simple example with No Handshake was chosen here, so that
no program or function module needs to be used for data transfer.
Provide 24 V DC supply for the CLV61x Dual Port and connect it with the PROFINET IO network.
S7 HW configuration:
• Install the CLV61x GSDML file in the PLC (S7 HW Config).
HW Config: "Install Extras / GSD", also see Chapter 4.1.
The CLV61x Dual Port is then added as follows in the S7 HW catalog:
"PROFINET IO / Additional FIELD DEVICES / Ident Systems / CLV61x, 2port"
• Drag the CLV61x Dual Port onto the PROFINET line.
Double click the CLV61x icon and allocate the PROFINET name.
This PN name is the individual identifier for the PN and must be clearly allocated for each relevant
device, e.g., "Scanner 10":
• When adding the CLV61x Dual Port, these four modules are added automatically:
Both of the modules Ctrl Bits In and Ctrl Bits Out must be used.
Both data modules can also be exchanged for smaller or larger ones if required.
The I/O address can be customized.