11 Alarms 09.91
11.9 General RESET alarms
Cause:
Effect:
Explanation:
An axis speed was specified which was larger than the maximum axis
speed (MD 280*)
Speed is reduced to maximum speed
• The programmed speed is greater than the tool path feedrate
resulting from the maximum speeds of the axes.
• During thread cutting G33 a spindle speed and a thread pitch were
programmed which would lead to an axis speed greater than the
maximum axis speed (MD 280*).
• One of the following data is greater than the maximum speed
• conventional feed (JOG)
• conventional rapid traverse (JOG)
• incremental speed
• reference point approach speed
Explanation:
Remedy:
2034
Speed reduction area
The software pre-limit switch has been overrun and the axes braked to
reduction speed.
• Check program
• MD0 - Pre-limit switch
• MD1 - Speed behind pre-limit switch
(reduction speed)
2035
Feed limitation
2036
During thread cutting.
The lead decrease in the thread is so great that a diameter of 0
or less would result at the end of the thread.
Program smaller lead decrease or shorter thread.
Scan:
Significance:
Remedy:
G35 thread lead decr. error
STOP
START
Must be greater than 0
11–24 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)