11 Alarms 01.93
11.11 Alarm list ACKNOWLEDGE
Explanation:
3200
e.g. 1N5 illegal working area limitation
N5 = axis number 5 (a number from 1 to 7 is possible)
1 =min. working area limitation
2=max. working area limitation
This alarm is issued when the entry for working area limitation is
beyond the permitted values. Together with this alarm, the values are
limited to the maximum possible. This alarm sinply indicates that this
limitation has taken place.
Explanation:
Remedy:
3201
Spindle not synchronized
Initiation of C axis mode without the spindle being synchronized. This
can occur if the spindle has not been rotated after POWER ON.
Rotate spindle.
Explanation:
Remedy:
3202
M19 still active
Initiation of rotary axis mode although M19 is still active.
Terminate M19.
11–48 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)