5 Performance Data / Operation
B36
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
Table 5-9 Characteristic data for PROFINET CBA communication, Fortsetzung
Characteristic Limit valueTypical value
Remote interconnections with acyclic transmission
Sampling frequency: sampling interval, min.
Possible values: 100, 200, 500, and 1000 ms
Fast value: 20%
Medium value: 40%
Slow value: 40%
100 ms minimum
Number of incoming interconnections 50 128 maximum
Number of outgoing interconnections 50 128 maximum
Data length of all incoming interconnections 2048 bytes 8192 bytes
Data length of all outgoing interconnections 2048 bytes 8192 bytes
Remote interconnections with cyclic transmission
Transmission frequency: transmission interval, min.
Possible values: 8, 16, 32, 64, 128, 256 and 512
ms
Fast value: 20%
Medium value: 40%
Slow value: 40%
8 ms minimum
Number of incoming interconnections 125 200
Number of outgoing interconnections 125 200
Data length of all incoming interconnections
Note:
The data length of all incoming interconnections
limited to 484 bytes gross per transmission
frequency and per partner station. Due to the
differences in header information, the net data
length depends on the data types being used.
In the best case, a maximum of 2 byte arrays with a
length of 238 bytes can be interconnected; in the
worst case, a maximum of 120 properties of the
type “Char” can be interconnected.
1000 bytes 2000 bytes
Data length of all outgoing interconnections 1000 bytes 2000 bytes
HMI variables over PROFINET (acyclic)
Number of stations that can register for HMI
variables (PN OPC/iMap)
Stations are 2 * PN OPC and 1 * SIMATIC iMap
3
HMI variable update 500 ms minimum
Number of HMI variables 200 maximum
Data length of all HMI variables 1600
*)
8192 bytes
Device-internal interconnections
Number of device-internal interconnections 50 256
Data length of all device-internal interconnections 400 bytes 2400 bytes
Interconnections with constants
Number of interconnections with constants 100 200 maximum
Data length of all interconnections with constants 1024 bytes 4096 bytes