9 Further Notes on Operation
B65
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
9.4.3 Obtaining the IP address over DHCP: CP STOP on expiry of the
lease
If you have configured “Obtain IP address from a DHCP server”, when the CP
starts up, it is assigned a valid IP address by the DHCP server for a restricted time
(period of the lease).
When the lease expires the reaction of the CP is as follows:
The CP changes to STOP and loses the previously assigned IP address if the
DHCP server does not extend it before expiry of the lease. All communication
connections are terminated.
9.5 PROFINET IO / IRT communication synchronization
types
Within an IRT domain (Isochronous Real Time), you can use the CP for IRT
communication.
You specify the required synchronization parameters in the properties dialog of the
PROFINET interface (HW Config: Row “X2 (<device name>)”) in the
“Synchronization” tab.
9.6 IP access protection via the IP access control list with a
PROFINET IO device
Please note the following when IP access protection is activated:
When you configure the CP as a PROFINET IO device, make sure that you enter
the IP address of the PROFINET IO controller in the IP access list.
9.7 Media redundancy
You can use the CP in a ring topology with media redundancy. The CP itself can be
redundancy manager or redundancy client.
You create the configuration in STEP 7 in the properties dialog of the PROFINET
interface in the “Media redundancy” tab (HW Config: Row “X2 (<device name>)”).
For more detailed information on configuration, refer to the online help of the
“Media redundancy” tab and in Part A of the manual.