CP 523 Print Mode
6.7.2 Setting the Time and Date (Job Number 10
H
)
Specify:
The new settings in bytes 1 to 7
Job number 10
H
in byte 0
In each case, you must transfer the settings first and the "Set clock" request last to the CP 523.
Settings
You must note the following as regards the settings:
The settings must be transferred to the CP 523 in BCD.
If you enter "FF
H
" in a setting, the current clock data is retained.
Specify the days of the week as follows:
01 = Sunday, 02 = Monday, 03 = Tuesday, 04 = Wednesday, 05 = Thursday, 06 = Friday,
07 = Saturday
AM/PM flag (only in the case of the 12h clock)
When specifying the "Hours" setting in byte 5, you must take account of the AM/PM flag
(bit 7) in the case of the 12h clock: bit 7 = 1 p.m. and bit 7 =0 a.m.
Table 6-22. Contents of the Transfer Memory for "Set Clock" Job
MeaningByte Value range
1
01
BCD
. . .07
BCD
2
3
4
01
BCD
. . .31
BCD
01
BCD
. . .12
BCD
00
BCD
. . .99
BCD
00
BCD
. . .23
BCD
01
BCD
. . .12
BCD
81
BCD
. ..92
BCD
6
7
5
00
BCD
. . .59
BCD
00
BCD
. . .59
BCD
0 10
H
Day of the week
(01 = Sunday, 02 = Monday, ..., 07 = Saturday)
Day
Month
Year
Hours
24 h clock
12 h clock a. m.
12 h clock p. m.
Minutes
Seconds
Job number for ”Set Clock”
6.7.3 Setting the Page Number (Job Number 20
H
)
When configuring the memory submodule, you can define whether and where a page number is
to be printed in parameter block 5. The default is pagination beginning with page number 1,
printed at the bottom centre of the page.
Specify
The page number in byte 1 (01
H
to FF
H
)
Job number 20
H
in byte 0.