Siemens KS7 Series Specifikace Strana 128

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 257
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 127
Communications Mode CP 523
Table 7-7. Parameter Block Assignments for 3964(R) Mode (Continued)
0 (for memory
submodule con-
figured with
message texts)
1 (no memory
submodule)
7 Mode
Print mode
Transparent mode
Interpretive mode
3964(R) mode
0
1
2
3
Character delay time (ZVZ)
(1 to 65535) ·10 ms
00001
D
to 65535
D
22
D
Block delay time (BWZ)
(1 to 65535) ·10 ms
00400
D
00001
D
to 65535
D
Transfer with block check character
(3964R)
Transfer without block check character
(3964)
0
Low
Priority
High
0
1
1
Connection buildup attempts
No. of Send attempts
001
D
to 255
D
001
D
to 255
D
6
6
1
0
00001
D
to 65535
D
00200
D
Time-out (QVZ)
(1 to 65535) ·10 ms
Example: Setting parameters on the MEMORY SUBMODULE for ”3964(R)” MODE over the
PG 685
Start address 128 is set on the CP 523. The module is to be operated in ”3964(R)” mode.
Parameters are to be set as follows:
Parameters for the serial interface (parameter block 0)
- 2400 baud (6)
- Even parity (0)
- No BUSY signal (0)
- V.24 (RS 232 C) interface (1)
- 7 data bits (11-bit frame) (0)
- Handshaking OFF (0)
Parameters for ”3964(R) mode” (parameter block 7)
- Character delay time 1 s (00100)
- Time-out 2 s (00200)
- Block delay time 4 s (00400)
- With block check character (1)
- Low priority (0)
- Buildup attempts (012)
- No. of Send attempts (003)
7-22
EWA 4NEB 811 6044-02a
Zobrazit stránku 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 256 257

Komentáře k této Příručce

Žádné komentáře