Siemens KS7 Series Specifikace Strana 84

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 257
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 83
CP 523 Print Mode
"KG", "KG." and "KG,", data format
If you configure the "KG" or "KG." data format, 13 characters are printed out. In the case of "KG"
and "KG,", a comma is printed out and in the case of "KG." a decimal point.
"KGa.b" data format
You can set the following parameters:
Specify the total number of characters to be printed with "a".
The sign and the decimal point each count as one character.
Configure the number of places after the point with "b".
The variable value is not changed here, in contrast to the "KFa.b" data format.
In the case of data format "KFa,b", a comma (between thousands) is printed out and, in the
case of "KFa.b", a decimal point.
Table 6-13. Value Ranges for the Number of Characters to be Printed and Decimal Places
Characters to be Printed ”a”
Decimal Places ”b” 0
1...9
1
3...9
2
4...9
3
5...9
4
6...9
5
7...9
6
8...9
Errors occurring when configuring the "KGa,b" format have the following effects:
If you specify values for "a" and "b" outside the value range, the spaceholder is treated as text
and printed as configured.
If you configure "a" with a value too small for the variable values to be printed, "?" characters
will be printed instead of the variable value.
Table 6-14. Typical "KGa.b" Data Format Printouts
Number to be
Represented
Configuration
KG9,0 KG9,4 KG9,6 KG6,3 KG5,4
3,141593E+01
31 31,415930 31,416 'KG 5,4'
31,4159
Number to be
Represented
Configuration
KG4,1 KG3,1 KG1,0
3,141593E+01 31,4 ?
31
EWA 4NEB 811 6044-02a
6-29
Zobrazit stránku 83