Overview of alarms 06/2009
NCK alarms
2-110
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: - Abort program with reset.
- Correct program on HMI or PC.
- Restart reloading (possibly with block search and interrupt location).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14700 [Channel %1: ] Block %2 timeout during command to interpreter
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A timeout has occurred in control-internal commands such as ANWAHL (part program selection),
RESET (channel reset), REORG (reorganization of the preprocessing buffer) and NEWCONFIG
(change in the configuration-specific machine data = restart).
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
If the runtime error occurred as the result of a temporary excessive load on the system (e.g. in the HMI
area or in OEM application) error-free execution is possible on repeating the program or operator
action.
Otherwise, the A&D MC system support should be contacted with a precise description of the error
situation:
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:see alarm 1000)
Program Con-
tinuation:
Switch control OFF - ON.
14701 [Channel %1: ] Block %2 number of available NC blocks reduced by %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Number of non-available blocks
Definitions: After reset, it has been found that the number of available blocks has decreased compared with the
last reset. This is due to a system error. Part program execution can be resumed after the alarm has
been acknowledged. If the number of blocks no longer available is less than MD28060
$MC_MM_IPO_BUFFER_SIZE, then the POWERON alarm 14700 is output.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Proceed as in the case of a system error.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14710 [Channel %1: ] Block %2 error in initialization sequence in function %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Identifier of the function which caused the error
Definitions: Initialization blocks are generated (or not) after control power-up, (program) RESET and (program)
START, depending on the settings in machine data MD20110 $MC_RESET_MODE_MASK and
MD20112 $MC_START_MODE_MASK.
Errors can occur because of incorrect machine data settings. The errors are output with the same error
messages as would appear if the function had been incorrectly programmed in the part program.
This alarm is also generated in order to indicate that an error relates to the initialization sequence.
Parameter %3 specifies which function triggers the alarm:
Control power-up and (program) RESET:
Value:
0: Error during synchronization preprocessing/main run
1: Error on selection of tool length compensation
2: Error on selection of transformation
3: Error on selection of work offset