Siemens SINUMERIK 802D sl Návod k obsluze Strana 190

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 340
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 189
Overview of alarms 06/2009
NCK alarms
2-190
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
26100 Axis %1 drive %2 sign of life missing
Parameters: %1 = Axis name, spindle number
%2 = Drive number
Definitions: Special case: The output of drive number=0 indicates that a computing timeout occurred on the IPO
level (see also alarm 4240)
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Restart drive, check drive software.
Program Con-
tinuation:
Switch control OFF - ON.
26101 Axis %1 drive %2 communication failure
Parameters: %1 = Axis name, spindle number
%2 = Drive number
Definitions: For PROFIdrive only:
The drive is not communicating.
Reaction: Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: - Check the bus configuration.
- Check the interface (connector removed, option module inactive, etc.).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
26102 Axis %1 drive %2 sign of life missing
Parameters: %1 = Axis name, spindle number
%2 = Drive number
Definitions: For PROFIdrive only:
The sign-of-life cell is no longer being updated by the drive.
Reaction: Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Axes of this channel must be re-referenced.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: - Check the cycle settings.
- Increase the cycle time if necessary.
- Power-up the drive again.
- Check drive software.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program