NCK alarms
06/2009 Overview of alarms
2-39
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
8030 [Channel %1: ] Block %2 option 'interpolation of more than %3 axes' not
set
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Number of permissible axes
Definitions: The option for the number of interpolating axes does not correspond to the number of axes pro-
grammed in the interpolation group.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: In the part program, program maximally the number of axes required for the relevant controller con-
figuration.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8040 Machine data %1 reset, corresponding option is not set
Parameters: %1 = String: MD identifier
Definitions: A machine data has been set that is locked by an option.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
For retrofitting the option, please refer to your machine manufacturer or to a sales representative of
SIEMENS AG, A&D MC.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8041 Axis %1: MD %2 reset, corresponding option not sufficient
Parameters: %1 = Axis number
%2 = String: MD identifier
Definitions: All of the axes selected in the machine data of the assigned option are used. Safety functions have
been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: --
Program Con-
tinuation:
Switch control OFF - ON.
8044 Option for IPO cycle time %1 ms not set
Parameters: %1 = Impermissible IPO cycle time
Definitions: The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
- Option-free >= 8ms
- 1. 1st step >= 6ms
- 2. 2nd step >= 4ms
- 3. 3rd step >= 2ms
- 4. 4th step <2ms
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: - Buy option
- Increase IPO cycle time (e.g. via MD10070 $MN_IPO_SYSCLOCK_TIME_RATIO)