Siemens SINUMERIK 802D sl Návod k obsluze Strana 320

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 340
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 319
System reactions on alarms 06/2009
Cancel criteria for alarms
4-320
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl,, Diagnostics Manual, 06/2009
4.1 Cancel criteria for alarms
Name ONE_IPO_CLOCK_DELAY_ALARM_REACTION
Effect All alarm reactions are delayed by one cycle when an alarm is output. This functionality
became necessary as part of ESR development.
All alarm reactions are delayed by one IPO cycle on alarm.
Name CANCELCLEAR
Effect The alarm is cleared by pressing the Cancel key in any channel. It is also cleared by the
Start part program key.
Clear the alarm with the Clear key or with NC START
Name CLEARHIMSELF
Effect Self-clearing alarm. The alarm is cleared not by an operator action but explicitly by a
"clearAlarm" in programmed the NCK source code.
The alarm is no longer displayed when the alarm cause has been removed. No
other operator actions are required.
Name NCSTARTCLEAR
Effect The alarm is cleared by starting a program in the channel, in which the alarm occurred.
The alarm is also cleared by an NC reset.
Clear the alarm with NC START or the RESET key and continue the program.
Name POWERONCLEAR
Effect The alarm is canceled by turning off / turning on the control system (POWER ON).
Switch the control OFF - ON.
Name RESETCLEAR
Effect The alarm is cleared by pressing the Reset key in the channel in which the alarm
occurred.
Clear alarm with the RESET key. Restart the part program.
Name BAGRESETCLEAR
Effect The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in
all channels of this mode group.
Press the RESET key to clear the alarm in all channels of this mode group. Restart
the part program.
Zobrazit stránku 319
1 2 ... 315 316 317 318 319 320 321 322 323 324 325 ... 339 340

Komentáře k této Příručce

Žádné komentáře