Overview of alarms 06/2009
NCK alarms
2-38
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Definitions: The NC card cannot be accessed because a valid write algorithm is not available for the flash memory.
Reaction: Alarm display.
Remedy: Use a compatible NC card or enter the new manufacturer code/device code in MD11700
$MN_PERMISSIVE_FLASH_TAB after consultation with SIEMENS.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
7500 Block %1 invalid protection level for command %2 (protection level act.:
%3 prog.: %4)
Parameters: %1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Definitions: On assigning a protection level for a parts program command via REDEF command
- an impermissible parts program command has been programmed
- a protection level has been programmed that is logically smaller (larger in value) than the protection
level currently applicable for this command.
- the relevant definition file has not been protected sufficently against write access. The write protec-
tion of the file must be at least as high as the highest protection level that has been assigned to a parts
program command in this definition file.
Reaction: Alarm display.
Remedy: Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UACCESS_DEF-
CESS_ DEF. Please see the Siemens Programming Guide or the OEM documentation for the lan-
guage commands permissible for the relevant system configurations.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8000 [Channel %1: ] Option 'Interrupt routines' not set
Parameters: %1 = Channel number
Definitions: Fast NCK inputs are required for the input signals in order to activate the interrupt routines and rapid
lift from contour. This function is not included in the basic version and must be retrofitted when needed.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Do not use rapid interrupt inputs or con-
tact the machine manufacturer with a view to retrofitting this option!
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8010 Option 'activation of more than %1 axes' not set
Parameters: %1 = Number of axes
Definitions: More machine axes have been defined through the MD20070 $MC_AXCONF_MACHAX_USED than
are allowed in the system.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. The sum of all axes that have been con-
figured through the channel-specific MD20070 $MC_AXCONF_MACHAX_USED, must not exceed
the maximum number of axes (dependent on configuration -> option, basic version: 4 axes).